Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가

이용수 0

영문명
Resolution Evaluation of a Pinhole Collimator according to the Aperture Diameter using Micro Deluxe Phantom
발행기관
대한핵의학기술학회
저자명
안병호(Byung Ho An) 연준호(Joon Ho Yeon) 김수영(Soo Young Kim) 최성욱(Sung Wook Choi)
간행물 정보
『핵의학기술』Vol.19 No.1, 3~11쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2015.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose It is hard to obtain high quality images of knee and T.M joint because of a lot of soft tissues in the knee and T.M joint area. Most conventional system for high resolution scintigraphy was used by 4 mm aperture pinhole collimator. Performance comparison of high-resolution pinhole SPECT for Micro deluxe phantom using conventional system. the aim of this study is to evaluate performance of each aperture according to the diameter size and the usefulness of 24-hour delayed bone scintigraphy. Materials and Methods In this study 6 mm, 8 mm diameter pinhole collimators were mounted on Siemens E.CAM systems. In order to evaluate performance evaluation of each aperture and Micro Deluxe phantom was used for performance comparison of conventional SPECT system, Projection data were obtained with 9 degree increment per 30 second. Transverse images were reconstructed using dedicated OSEM algorithm with recovery of detector blurring. 99mTc-HDP source was used for 24-hour delayed bone scintigraphy. Results The knee joint images obtained with 24-hour delay were improved more than those obtained with 3-hour delay in our study. The 6 mm and 8 mm pinhole collimators FWHM have improved by 28% SNR and Uniformity have improved by 35%, Contrast has improved by 7% in 24-hour delayed knee joint image. While in 24-hour delayed T.M joint image of the 6 mm and 8 mm pinhole collimators FWHM have decreased by 60% SNR has decreased by 20% and Uniformity has decreased by 25%, Contrast has decreased significantly. Conclusion Pinhole collimators with 6 mm and 8 mm diameter could offer a superior performance for 24-hour delayed bone scintigraphy. The use of 24-hour delayed image provides additional benefits for pinhole scintigraphy of knee joint. Therefore, we expect that it is useful for precise diagnosis of knee joint and it is applicable to others joint imaging.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

안병호(Byung Ho An),연준호(Joon Ho Yeon),김수영(Soo Young Kim),최성욱(Sung Wook Choi). (2015).Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가. 핵의학기술, 19 (1), 3-11

MLA

안병호(Byung Ho An),연준호(Joon Ho Yeon),김수영(Soo Young Kim),최성욱(Sung Wook Choi). "Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가." 핵의학기술, 19.1(2015): 3-11

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제