학술논문
전신 뼈검사에서의 영상 평가 연구
이용수 5
- 영문명
- Study on Image Quality Assessment in Whole Body Bone Scan
- 발행기관
- 대한핵의학기술학회
- 저자명
- 권오준(Oh Jun Kwon) 허재(Jae Hur) 이한울(Han Wool Lee) 김주연(Joo Yeon Kim) 박민수(Min Soo Park) 노동욱(Dong Ook Roo) 강천구(Chun Goo Kang) 김재삼(Jae Sam Kim)
- 간행물 정보
- 『핵의학기술』Vol.19 No.1, 30~36쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2015.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Whole body bone scan, which makes up a largest percentage of nuclear medicine tests, has high sensitivity and resolution about bone lesion like osteomyelitis, fracture and the early detection of primary cancer. However, any standard for valuation has not yet been created except minimum factor. Therefore, in this study, we will analysis the method which show a quantitative evaluation index in whole body bone scan. Materials and Methods This study is conducted among 30 call patients, who visited the hospital from April to September 2014 with no special point of view about bone lesion, using GE INFINIA equipment. Enumerated data is measured mainly with patient's whole body count and lumbar vertabrae, and the things which include CNR (Contrast to Noise ratio), SNR (Signal to Noise ratio) are calculated according to the mean value signal and standard deviation of each lumbar vertabrae. In addition, the numerical value with the abdominal thickness is compared to each value by the change of scan speed and tissue equivalent material throughout the phantom examination, and compared with 1hours deleyed value. Completely, on the scale of ten, 2 reading doctors and 5 skilled radiologists with 5-years experience analysis the correlation between visual analysis with blind test and quantitative calculation. Results The whole body count and interest region count of patients have no significant correlation with visual analysis value throughout the blind test(ρ<0.05). There is definite correlation among CNR and SNR. In phantom examination, Value of the change was caused by the thickness of the abdomen and the scan speed. And The poor value of the image in the subject as a delay test patient could be confirmed that the increase tendency. Conclusion Now, a standard for valuation has not been created in whole body bone scan except minimum factor. In this study, we can verify the significant correlation with blind test using CNR and SNR and also assure that the scan speed is a important factor to influence the imagine quality from the value. It is possible to be some limit depending on the physiology function and fluid intake of patient even if we progress the evaluation in same condition include same injection amount, same scan speed and so on. However, that we prove the significant evaluation index by presenting quantitative calculation objectively could be considered academic value.
목차
서론
대상 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- PET/CT 검사에서 선량변화와 QAC기법 적용 시 Metal Artifact 유무에 따른 SUV 비교분석
- 주성분분석을 이용한 C[11]-PIB imaging 영상분석
- 18F-FDG Brain PET/CT 검사를 위한 데이터 비교 방법의 평가
- Micro Deluxe Phantom을 통한 핀홀 콜리메이터 초점의 직경별 분해능 평가
- DIACON 정도관리물질의 평가
- 전신 뼈검사에서의 영상 평가 연구
- PET 검사실 종사자의 업무 행위 별 방사선피폭 조사에 따른 피폭선량 저감화를 위한 연구
- 심장기능상태의 분류에 따른 게이트심장혈액풀 검사와 심장초음파의 심박출계수 상관관계에 관한 고찰
- Dynamic study를 이용한 선조체에서의 ¹⁸F-DOPA의 분포에 대한 평가
- 혈중 Estradiol 농도 측정을 위한 여러 방사면역측정 검사키트 및 화학면역발광 검사법의 성능평가 및 상호비교
- ⁹⁹ᵐTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!