본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

⁹⁹ᵐTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰

이용수 0

영문명
Study on the Usefulness of Using Anterior and Posterior Views for Calculation of Total Relative Uptake Ratio in ⁹⁹ᵐTc-DMSA Renal Scan
발행기관
대한핵의학기술학회
저자명
김주연(Joo-Yeon Kim) 이한울(Han-Wool Lee) 권오준(O-Jun Kwon) 김정열(Jung-Yul Kim) 박민수(Min-Soo Park) 조석원(Seok-Won Cho) 강천구(Chun-Goo Kang) 김재삼(Jae-Sam Kim)
간행물 정보
『핵의학기술』Vol.19 No.1, 37~43쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2015.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose ⁹⁹ᵐTc-DMSA renal scintigraphy serves as location, size and shape of kidney, so it has been used for diagnosis and passage observation after the operation or treatment. There are 3 methods of calculating the relative renal uptake ratio such as geometric mean of the counts from the anterior and posterior views, arithmetical mean from the only posterior view and posterior view which applied the renal depths. In this study, we seek to correlation between the change of total relative uptake ratio according to different inspection methods of obtaining the renal count rate. Materials and Methods The phantom experiments proceeded 5 times depending on each renal depth with the kidney phantom and tissue equivalent materials. In the clinical research, we investigated 36 adult patients who had visited our hospital from february to october, 2014 and received ⁹⁹ᵐTc-DMSA renal scan. The equipment was used as a gamma camera named INFINIA (General Electric Healthcare, milwaukee, USA) and we drew the region of interests through semiautomatic method by using Xeleris Ver. 2.1220 of GE. In addition, we obtained the lateral view of kidney to measure the renal depth of each patient. Then the results were compared with 3 methods of calculating relative renal uptake ratio. Results The phantom studies show when the difference between the left ant right kidney depth were less than 1 cm, there were no statistically significant difference among values calculated through anterior and posterior views and only posterior view (P>0.05), while the excess of 1cm, the results showed a statistically significant change in the value (P<0.05). In case of clinical research, the correlation between total relative uptake ratio by obtaining both sides of image and posterior view applied the kidney depth (r=0.999) was higher than by obtaining only posterior view and applying the kidney depth to one side image (r=0.988). Conclusion This study has found that, the difference of calculating total relative uptake ratio compared with obtaining anterior and posterior views and only posterior view. In order to reduce the error, we recommend the method of obtaining anterior and posterior views and is considered to be useful, particularly the patients have similar uptake ratio of left and right kidney and difficulties of measurements of kidney depth.

목차

서론
실험 대상 및 방법
결과
결론 및 고찰
요약
REFERENCE

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김주연(Joo-Yeon Kim),이한울(Han-Wool Lee),권오준(O-Jun Kwon),김정열(Jung-Yul Kim),박민수(Min-Soo Park),조석원(Seok-Won Cho),강천구(Chun-Goo Kang),김재삼(Jae-Sam Kim). (2015).⁹⁹ᵐTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰. 핵의학기술, 19 (1), 37-43

MLA

김주연(Joo-Yeon Kim),이한울(Han-Wool Lee),권오준(O-Jun Kwon),김정열(Jung-Yul Kim),박민수(Min-Soo Park),조석원(Seok-Won Cho),강천구(Chun-Goo Kang),김재삼(Jae-Sam Kim). "⁹⁹ᵐTc-DMSA 검사에서 상대 신섭취율 산출 시 양면상 촬영의 유용성에 대한 고찰." 핵의학기술, 19.1(2015): 37-43

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제