Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가

이용수 0

영문명
The Evaluation of Resolution Recovery Based Reconstruction Method, Astonish
발행기관
대한핵의학기술학회
저자명
승종민(Jong Min Seung) 이형진(Hyeong Jin Lee) 김진의(Jin Eui Kim) 김현주(Hyun Joo Kim) 김중현(Joong Hyun Kim) 이재성(Jae Sung Lee) 이동수(Dong Soo Lee)
간행물 정보
『핵의학기술』Vol.15 No.1, 58~64쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2011.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objective: The 3-dimensional reconstruction method with resolution recovery modeling has advantages of high spatial resolution and contrast because of its precise modeling of spatial blurring according to the distance from detector plane. The aim of this study was to evaluate one of the resolution recovery reconstruction methods (Astonish, Philips Medical), compare it to other iterative reconstructions, and verify its clinical usefulness. Materials and Methods: NEMA IEC PET body phantom and Flanges Jaszczak ECT phantom (Data Spectrum Corp., USA) studies were performed using Skylight SPECT (Philips) system under four different conditions; short or long (2 times of short) radius, and half or full (40 kcts/frame) acquisition counts. Astonish reconstruction method was compared with two other iterative reconstructions; MLEM and 3D-OSEM which vendor supplied. For quantitative analysis, the contrast ratios obtained from IEC phantom test were compared. Reconstruction parameters were determined by optimization study using graph of contrast ratio versus background variability. The qualitative comparison was performed with Jaszczak ECT phantom and human myocardial data. Results: The overall contrast ratio was higher with Astonish than the others. For the largest hot sphere of 37 mm diameter, Astonish showed about 27.1% and 17.4% higher contrast ratio than MLEM and 3D-OSEM, in short radius study. For long radius, Astonish showed about 40.5% and 32.6% higher contrast ratio than MLEM and 3D-OSEM. The effect of acquired counts was insignificant. In the qualitative studies with Jaszczak phantom and human myocardial data, Astonish showed the best image quality. Conclusion: In this study, we have found out that Astonish can provide more reliable clinical results by better image quality compared to other iterative reconstruction methods. Although further clinical studies are required, Astonish would be used in clinics with confidence for enhancement of images.

목차

서론
실험재료 및 방법
결과
결론 및 고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

승종민(Jong Min Seung),이형진(Hyeong Jin Lee),김진의(Jin Eui Kim),김현주(Hyun Joo Kim),김중현(Joong Hyun Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). (2011).Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가. 핵의학기술, 15 (1), 58-64

MLA

승종민(Jong Min Seung),이형진(Hyeong Jin Lee),김진의(Jin Eui Kim),김현주(Hyun Joo Kim),김중현(Joong Hyun Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). "Resolution Recovery 기반의 Astonish 영상 재구성 기법의 평가." 핵의학기술, 15.1(2011): 58-64

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제