본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가

이용수 0

영문명
Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose
발행기관
대한핵의학기술학회
저자명
권오진(Oh Jin Kweon) 정서희(Su Hee Jung) 백승찬(Seung Chan Baek) 김경호(Kyeong Ho Kim)
간행물 정보
『핵의학기술』Vol.13 No.1, 93~97쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: Recognize circulation work system and fixing work system’s merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: ① Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. ② Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination’s number was 14,674 items until 2 quarters 2006~2008 year, and the ¹⁸F-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area’s circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse’s exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate ¹⁸F-FDG injection, and another is consultation about patient’s next time schedule after examination end. Although exposure dose’s amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, 131I-isotope therapy area’s radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose’s decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people’s business efficiency decline.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

권오진(Oh Jin Kweon),정서희(Su Hee Jung),백승찬(Seung Chan Baek),김경호(Kyeong Ho Kim). (2009).근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가. 핵의학기술, 13 (1), 93-97

MLA

권오진(Oh Jin Kweon),정서희(Su Hee Jung),백승찬(Seung Chan Baek),김경호(Kyeong Ho Kim). "근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가." 핵의학기술, 13.1(2009): 93-97

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제