학술논문
Open Source를 이용한 MicroPACS의 구성과 활용
이용수 0
- 영문명
- Application of MicroPACS Using the Open Source
- 발행기관
- 대한핵의학기술학회
- 저자명
- 유연욱(Yeon Wook You) 김용근(Yong Keun Kim) 김영석(Yeong Seok Kim) 원우재(Woo Jae Won) 김태성(Tae Sung Kim) 김석기(Seok Ki Kim)
- 간행물 정보
- 『핵의학기술』Vol.13 No.1, 51~56쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as “retrieve”, “query”. Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, ① It must be available in Windows Operating System. ② It must be free ware. ③ It must be compatible with PET/CT scanner. ④ It must be easy to use. ⑤ It must not be limited of storage capacity. ⑥ It must have DICOM supporting. 2. ① To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. ② To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. ① Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. ② The wasted time (sec) to find some data is as follows: CD (156±46), DVD-RAM (115±21) and Conquest DICOM Server (13±6). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.
목차
서론
실험재료 및 방법
결과
결론
요약
REFERENCES
해당간행물 수록 논문
- I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용
- Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가
- PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향
- PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성
- Brain SPECT Processing에 있어서 Macro Program 사용의 유용성
- Open Source를 이용한 MicroPACS의 구성과 활용
- Dual detector system에서 Brain SPECT의 new reconstruction method의 연구
- 골밀도 상태에 따른 검사자의 재현성 평가
- SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가
- PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향
- 전혈에서 시간과 온도에 따른 Adrenocorticotropic Hormone의 안정성 평가
- 건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정
- 근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가
- 건강검진 종목으로서 항갑상선 과산화효소 항체검사의 유용성에 대한 평가
- Cr-51 EDTA GFR 검사 결과의 분석 및 의의
- 타액선 신티그라피 검사에서 타액선 영상과 타액 제거율의 비교 연구
- PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가
- Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가
- Onco Flash에서 매개변수 변화에 따른 영상의 질 평가
- 영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교
- 소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사
- 운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!