학술논문
PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성
이용수 0
- 영문명
- Usefulness of Stomach Extension after Drinking Orange Juice in PET/CT Whole Body Scan
- 발행기관
- 대한핵의학기술학회
- 저자명
- 조석원(Seok Won Cho) 정석(Seok Chung) 오신현(Shin Hyun Oh) 박훈희(Hoon Hee Park) 김재삼(Jae Sam Kim) 이창호(Chang Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.13 No.1, 86~92쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: The PET/CT has a clear distinction on the lesion of the functional image by adding anatomical information. It also could reduce the examination time using CT data as the attenuation-correction. When the stomach was contracted from a fast, it could bring a misinterpretation of the cancer of the lesion with a presence of physiological ¹⁸F-FDG uptake in stomach and it occasionally would bring an additional scan to confirm. To complement this shortcoming, the method that the patients had water before the examination to extend the stomach had been attempted. However, a short excretion time of the stomach did not give sufficiently extended image of the stomach. Then the patients had additional water and had the examination again. Therefore, the noticed fact is that the stomach excretion time depends on calories, protein content, and the level of carbohydrate. In this study, we use an orange juice to evaluate the extension of the stomach and usefulness of it. Materials and Methods: PET/CT scan were obtained on total 150 of patient from February 2008 to October2008, There were 3 groups in this study and each group had 50 patients. First group drank nothing, Second group drank water and third group drank orange juice. The patients (man 25, female 25) not drinking are the age of 30~71 years old (average: 54), the patients (man: 25, female: 25) drinking water (400 cc) are the age of 28~71 years old (average: 54) and the patients (man: 25, female: 25) drinking orange juice (400 cc) are the age of 32~74 years old (average: 56). The patients were fasted in 6-8 hours before the test, the patients were not diabetic. ¹⁸F-FDG 370~555 MBq were injected intravenously. The patients were in stable position for 1 hour, than the image was obtained. The patients drank water and other patients drank orange juice before Whole body scan. The image scan started from mid-femur to skull base. The emission scan acquired for three minutes per bed and the images were reconstructed. Stomach extension analysis is measured from vertical and horizontal length. Results: Stomach Extension was described as the vertical length of the Non Drink Group was 1.20±0.50 cm, horizontal length was 1.4±0.53 cm, the vertical length of the Water Drink Group was 1.67±0.63 cm, horizontal length was 1.65±0.77 cm, the vertical length of Orange juice Drink Group was 3.48± 0.77 cm, horizontal length was 3.66±0.77 cm in coronal image. Stomach Extension was described the vertical length of the Non Drink Group was 2.03±0.62 cm, horizontal length was 1.69±0.68 cm, the vertical length of Water Drink Group was 5.34±1.62 cm, horizontal length was 2.45±0.72 cm, the vertical length of Orange juice Drink Group was 7.74±1.62 cm, horizontal length was 3.57±0.77 cm in transverse image. The Stomach Extension has specific differences (p<0.001). The SUVs shows the Non Drink Group were measured as Liver 2.52±0.42, Lung 0.51±0.14, the Water Drink Group were measured as Liver 2.47±0.38, Lung 0.50±0.14, Orange juice Drink Group were measured as Liver 2.47±0.38, Lung 0.50±0.14. The SUVs did not have specific differences (p>0.759). Conclusions: There was not a large difference of SUV in three groups. When the patients drank Orange juice and water, the range extension of stomach was higher than without drinking nothing and it was possible to acquire fully extended images. Therefore, it will be possible that unnecessary additional stomach scans will be reduced by drinking orange juice before the examination so that the patients’ claim from uncomfortable and long period of fast will be minimized.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
키워드
해당간행물 수록 논문
- I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용
- Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가
- PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향
- PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성
- Brain SPECT Processing에 있어서 Macro Program 사용의 유용성
- Open Source를 이용한 MicroPACS의 구성과 활용
- Dual detector system에서 Brain SPECT의 new reconstruction method의 연구
- 골밀도 상태에 따른 검사자의 재현성 평가
- SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가
- PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향
- 전혈에서 시간과 온도에 따른 Adrenocorticotropic Hormone의 안정성 평가
- 건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정
- 근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가
- 건강검진 종목으로서 항갑상선 과산화효소 항체검사의 유용성에 대한 평가
- Cr-51 EDTA GFR 검사 결과의 분석 및 의의
- 타액선 신티그라피 검사에서 타액선 영상과 타액 제거율의 비교 연구
- PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가
- Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가
- Onco Flash에서 매개변수 변화에 따른 영상의 질 평가
- 영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교
- 소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사
- 운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!