국문 초록
영문 초록
Purpose: Diagnostic and functional imaging softwares in Nuclear Medicine have been developed significantly. But, there are some limitations which like take a lot of time. In this article, we introduced that the basic concept of macro to help understanding macro and its application to Brain SPECT processing. We adopted macro software to SPM processing and PACS verify processing of Brain SPECT processing. Materials and Methods: In Brain SPECT, we choose SPM processing and two PACS works which have large portion of a work. SPM is the software package to analyze neuroimaging data. And purpose of SPM is quantitative analysis between groups. Results are made by complicated process such as realignment, normalization, smoothing and mapping. We made this process to be more simple by using macro program. After sending image to PACS, we directly input coordinates of mouse using simple macro program for processes of color mapping, adjustment of gray scale, copy, cut and match. So we compared time for making result by hand with making result by macro program. Finally, we got results by applying times to number of studies in 2007. Results: In 2007, the number of SPM studies were 115 and the number of PACS studies were 834 according to Diamox study. It was taken 10 to 15 minutes for SPM work by hand according to expertness and 5 minutes and a half was uniformly needed using Macro. After applying needed time to the number of studies, we calculated an average time per a year. When using SPM work by hand according to expertness, 1150 to 1725 minutes (19 to 29 hours) were needed and 632 seconds (11 hours) were needed for using Macro. When using PACS work by hand, 2 to 3 minutes were needed and for using Macro, 45 seconds were needed. After applying theses time to the number of studies, when working by hand, 1668 to 2502 minutes (28 to 42 hours) were needed and for using Macro, 625 minutes (10 hours) were needed. Following by these results, it was shown that 1043 to 1877 (17 to 31 hours were saved. Therefore, we could save 45 to 63% for SPM, 62 to 75% for PACS work and 55 to 70% for total brain SPECT processing in 2007. Conclusions: On the basis of the number of studies, there was significant time saved when we applied Macro to brain SPECT processing and also it was shown that even though work is taken a little time, there is a possibility to save lots of time according to the number of studies. It gives time on technologist’s side which makes radiological technologist more concentrate for patients and reduce probability of mistake. Appling Macro to brain SPECT processing helps for both of radiological technologists and patients and contribute to improve quality of hospital service.
목차
서론
실험재료 및 방법
결과
결론
요약
REFERENCES
키워드
해당간행물 수록 논문
- I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용
- Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가
- PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향
- PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성
- Brain SPECT Processing에 있어서 Macro Program 사용의 유용성
- Open Source를 이용한 MicroPACS의 구성과 활용
- Dual detector system에서 Brain SPECT의 new reconstruction method의 연구
- 골밀도 상태에 따른 검사자의 재현성 평가
- SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가
- PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향
- 전혈에서 시간과 온도에 따른 Adrenocorticotropic Hormone의 안정성 평가
- 건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정
- 근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가
- 건강검진 종목으로서 항갑상선 과산화효소 항체검사의 유용성에 대한 평가
- Cr-51 EDTA GFR 검사 결과의 분석 및 의의
- 타액선 신티그라피 검사에서 타액선 영상과 타액 제거율의 비교 연구
- PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가
- Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가
- Onco Flash에서 매개변수 변화에 따른 영상의 질 평가
- 영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교
- 소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사
- 운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!