학술논문
Dual detector system에서 Brain SPECT의 new reconstruction method의 연구
이용수 0
- 영문명
- The Study of New Reconstruction Method for Brain SPECT on Dual Detector System
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이형진(Hyung Jin Lee) 김수미 이홍재(Hong Jae Lee) 김진의(Jin Eui Kim) 김현주(Hyun Joo Kim)
- 간행물 정보
- 『핵의학기술』Vol.13 No.1, 57~62쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: Brain SPECT study is more sensitive to motion than other studies. Especially, when applying 1-day subtraction method for Diamox SPECT, it needs shorter study time in order to prevent reexamination. We were required to have new study condition and analysing method on dual detector system because triple head camera in Seoul National University Hospital is to be disposed. So we have tried to increase image quality and make the dual and triple head to have equivalent study time by using a new analysing program. Materials and Methods: Using IEC phantom, we estimated contrast, SNR and FWHM. In Hoffman 3D brain phantom which is similar with real brain, we were on the supposition that 5% of injected doses were distributed in brain tissue. To compare with existing FBP method, we used fan-beam collimator. And we applied 15 sec, 25 sec/frame for each SEPCT studies using LEHR and LEUHR. We used OSEM2D and Onco-flash3D reconstruction method and compared reconstruction methods between applied Gaussian post-filtering 5mm and not applied as well. Attenuation correction was applied by manual method. And we did Brain SPECT to patient injected 15 mCi of 99mTc- HMPAO according to results of Phantom study. Lastly, technologist, MD, PhD estimated the results. Results: The study shows that reconstruction method by Flash3D is better than exiting FBP and OSEM2D when studied using IEC phantom. Flowing by estimation, when using Flash3D, both of 15 sec and 25 sec are needed postfiltering 5 mm. And 8 times are proper for subset 8 iteration in Flash3D. OSEM2D needs post-filtering. And it is proper that subset 4, iteration 8 times for 15sec and subset 8, iteration 12 times for 25sec. The study regarding to injected doses for a patient and study time, combination of input parameter-15 sec/frame, LEHR collimator, analysing program-Flash3D, subset 8, iteration 8times and Gaussian post-filtering 5mm is the most appropriate. On the other hands, it was not appropriate to apply LEUHR collimator to 1-day subtraction method of Diamox study because of lower sensitivity. Conclusions: We could prove that there was also an advantage of short study time effectiveness in Dual camera same as Triple gamma camera and get great result of alternation from existing fan-beam collimator to parallel collimator. In addition, resolution and contrast of new method was better than FBP method. And it could improve sensitivity and accuracy of image because lesser subjectivity was input than Metz filter of FBP. We expect better image quality and shorter study time of Brain SPECT on Dual detector system.
목차
서론
실험재료 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용
- Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가
- PET/CT 영상에서 조영제를 이용한 CT 영상의 보정(Correction)에 따른 표준화섭취계수(SUV)의 영향
- PET/CT 전신 영상에서 오렌지 주스(Orange Juice)를 이용한 위장 확장 영상의 유용성
- Brain SPECT Processing에 있어서 Macro Program 사용의 유용성
- Open Source를 이용한 MicroPACS의 구성과 활용
- Dual detector system에서 Brain SPECT의 new reconstruction method의 연구
- 골밀도 상태에 따른 검사자의 재현성 평가
- SPECT 검사에서 Onco Flash의 유용성과 질적 향상 평가
- PET/CT검사에서 CT의 확대 유효시야 적용이 표준화섭취계수에 미치는 영향
- 전혈에서 시간과 온도에 따른 Adrenocorticotropic Hormone의 안정성 평가
- 건강검진이 의뢰된 여성의 연령에 따른 Osteocalcin의 참고범위 설정
- 근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가
- 건강검진 종목으로서 항갑상선 과산화효소 항체검사의 유용성에 대한 평가
- Cr-51 EDTA GFR 검사 결과의 분석 및 의의
- 타액선 신티그라피 검사에서 타액선 영상과 타액 제거율의 비교 연구
- PET 검사에서 Iterative 재구성 방법과 True X 재구성 방법에 따른 영상의 균일성 및 대조도 비교 평가
- Lymphoscintigraphy에 이용되는 방사성의약품의 사용제한으로 인한 대체 방사성의약품의 성능평가
- Onco Flash에서 매개변수 변화에 따른 영상의 질 평가
- 영상 재구성 방법에 따른 Bone SPECT 영상의 질과 검사시간에 대한 실효성 비교
- 소아 핵의학 검사 시 사용되는 방사성의약품의 양 산출 기준 조사
- 운동유무에 따른 양측 대퇴골 골밀도 차이에 관한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!