Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가

이용수 0

영문명
Usefulness Assessment of Automatic Analysis Program for Flangeless Esser PET Phantom Images
발행기관
대한핵의학기술학회
저자명
남궁창경(Chang Kyeong Namgung) 남기표(Ki Pyo Nam) 김경식(Kyeong Sik Kim) 김정선(Jeong Seon Kim) 임기천(Ki Cheon Lim) 신상기(Sang Ki Shin) 조시만(Shee Man Cho) 동경래(Kyung Rae Dong)
간행물 정보
『핵의학기술』Vol.13 No.1, 63~66쪽, 전체 4쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: ACR (American College of Radiology) offers variable parameters to PET/CT quality control by using ACR Phantom. ACR Phantom was made to evaluate parameters which are uniformity, attenuation, scatter, contrast and resolution. Manual analysis method wasn’t good for the use of QC because values of parameter were changed as it may user and it takes long time to analysis. Ki-Chun Lim, a nuclear scientist in AMC, developed program that automatically analysis values of parameter by using ACR Phantom to overcome above problems. In this study, we evaluated automatic analysis program’s usability, through the comparing SUV of each method, reproducibility of SUV when repeated analysis and the time required. Materials and Methods: Using Flangeless Esser PET Phantom, the ideal ratio of 4 : 1 hot cylinder and BKG but it actually showed a ratio of 3.89 to 1 hot cylinder and BKG. SIEMENS Biograph True Point 40 was used in this study. We obtained images using ACR phantom at Fusion WB PET Scan condition (2 min/bed) and 120 kV, 100 mAs CT condition. Using True X method, 3 iterations, 14 subsets, Gaussian filter, FWHM 4 mm and Zoom Factor 1.0, 168×168 image size. We obtained Max. & Min. SUV and SUV Mean values at Cylinder (8, 12, 16, 25 mm, Air, Bone, Water, BKG) by automatic program and obtained SUV by manual method. After that, we compared manual and automatic method. we estimate the time required from opened the image data to final work sheet was completed. Results: Automatic program always showed same result and same the time required. At 8, 12, 16 and 25 m cylinder, manual method showed 6.69, 3.46, 2.59, 1.24 CV values. The larger cylinder size became, the smaller CV became. In manual method, bone, air, water’s CV were over 9.9 except BKG (2.32). Obtained CV of Mean SUV showed BKG was low (0.85) and bone was high (7.52). The time required was 45 second, 882 second respectably. Conclusions: As a result of difference automatic method and manual method, automatic method showed always same result, manual method showed that the smaller hot cylinders became, the lager CV became. Hot cylinders mean region size, the smaller hot cylinder size becomes we had some trouble in doing ROI poison setting. And it means increase in variation of SUV. The Study showed the time required of automatic method was shorten then manual method.

목차

서론
실험재료 및 방법
결과
결론
고찰
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

남궁창경(Chang Kyeong Namgung),남기표(Ki Pyo Nam),김경식(Kyeong Sik Kim),김정선(Jeong Seon Kim),임기천(Ki Cheon Lim),신상기(Sang Ki Shin),조시만(Shee Man Cho),동경래(Kyung Rae Dong). (2009).Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가. 핵의학기술, 13 (1), 63-66

MLA

남궁창경(Chang Kyeong Namgung),남기표(Ki Pyo Nam),김경식(Kyeong Sik Kim),김정선(Jeong Seon Kim),임기천(Ki Cheon Lim),신상기(Sang Ki Shin),조시만(Shee Man Cho),동경래(Kyung Rae Dong). "Flangeless Esser PET Phantom 영상 자동 분석 프로그램의 유용성 평가." 핵의학기술, 13.1(2009): 63-66

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제