본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

고도근시에서 시신경유두주위 위축 범위에 따른 빛간섭단층촬영의 녹내장 진단력 비교

이용수 7

영문명
Comparison of Diagnostic Power Among OCT Parameters According to Peripapillary Atrophy in High Myopic Glaucoma
발행기관
대한안과학회
저자명
김우진 김경남 김창식,Woo Jin Kim, MD, Kyung Nam Kim, MD, Chang Sik Kim, MD, PhD,
간행물 정보
『대한안과학회지』Ophthalmological Society,volume54,number12, 1844~1855쪽, 전체 12쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2013.12.13
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To evaluate diagnostic power to detect glaucoma in high myopic eyes with peripapillary atrophy among optical coherence tomography (OCT) parameters. Methods: Fifty eyes of 31 glaucoma patients with myopia of -6.00 diopters or less and a peripapillary atrophy (PPA) were classified into a group with a PPA located beyond the circumpapillary OCT scan circle (group A) and a group with a PPA confined within the scan circle (group B). Circumpapillary retinal nerve fiber layer (cpRNFL), total macula (TM), and ganglion cell-inner plexiform layer (GCIPL) thickness were measured in each group and the diagnostic power of each measurement was compared by area under the receiver operating characteristic curve (AUC). Results: There were no significant differences in the age, gender, intraocular pressure, optic disc size, and mean deviation between the 2 groups. The spherical equivalent of group A was significantly larger than group B (mean -11.9 vs. -7.3 diopters, p = 0.002). In group A, the AUC of average GCIPL thickness was significantly higher than average cpRNFL and average TM thickness (p < 0.05). Additionally, when comparing parameters that showed the highest AUC value in each method, the AUC of GCIPL thickness was significantly higher than cpRNFL thickness (p = 0.046). In subgroup analysis of spherical equivalent matching between the 2 groups (subgroup A and B), the highest AUC value of GCIPL thickness was significantly higher than cpRNFL and TM thickness in subgroup A (p < 0.05). In group B and subgroup B, there was no statistical significance among AUC values of the 3 different methods (p > 0.05). Conclusions: Assessment of GCIPL parameters is a useful technique for glaucoma diagnosis in patients with high myopia and PPA extending beyond circumpapillary OCT scan circle.
J Korean Ophthalmol Soc 2013;54(12):1844-1855

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김우진,김경남,김창식,Woo Jin Kim, MD, Kyung Nam Kim, MD, Chang Sik Kim, MD, PhD,. (2013).고도근시에서 시신경유두주위 위축 범위에 따른 빛간섭단층촬영의 녹내장 진단력 비교. 대한안과학회지, 54 (12), 1844-1855

MLA

김우진,김경남,김창식,Woo Jin Kim, MD, Kyung Nam Kim, MD, Chang Sik Kim, MD, PhD,. "고도근시에서 시신경유두주위 위축 범위에 따른 빛간섭단층촬영의 녹내장 진단력 비교." 대한안과학회지, 54.12(2013): 1844-1855

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제