본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

구면렌즈 C-flex™(570C)와 비구면렌즈 C-flex™(970C)의 임상적 유용성의 비교

이용수 0

영문명
Comparison of the Clinical Effects of Implantation of Aspheric and Spherical Intraocular Lenses
발행기관
대한안과학회
저자명
이종수 윤태진 안진환,Jong Soo Lee, MD, PhD, Tae-Jin Yoon, MD, Jin Hwan Ahn, MD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume50,number10, 1514~1519쪽, 전체 6쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2009.10.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To compare postoperative visual acuity, spherical equivalent and contrast sensitivity of eyes implanted with either spherical C-flex™(570C) or aspheric C-flex™(970C) intraocular lenses (IOL). Methods: Forty eyes implanted with posterior chamber intraocular lenses were divided into two groups: C-flex™(570C) (20 eyes) and C-flex™(970C) (20 eyes). In these two groups, postoperative best corrected visual acuity (logMAR), spherical equivalent and contrast sensitivity was performed at one month and three months, postoperatively. Results: In the spherical group, the preoperative naked visual acuity was 1.25±0.46 (logMAR). The best corrected visual acuity at postoperative three months was 0.49±0.28. In the aspheric group, the preoperative naked visual acuity was 1.29±0.67. The bestcorrected visual acuity at postoperative three months was 0.39±0.30. There were statistically significant differences in best-corrected visual acuity between the preoperative and the postoperative three months results in the spherical IOL group and in the aspherical IOL group. There were no statistically significant differences in spherical equivalent between preoperative and postoperative onemonth results and between preoperative and postoperative three-month results in the spherical IOL group and the aspherical IOL group. In the aspherical IOL group, contrast sensitivity at postoperative one and three months were better in the all spatial frequency than in the preoperative scotopic condition. Conclusions: When we compared eyes implanted with the spherical C-flex™(970C) with eyes implanted with the spherical C-flex™ (570C), there were no statistically significant differences in spherical equivalent or best corrected visual acuity. The aspherical IOL group showed better contrast sensitivity than did the spherical IOL group postoperatively at both one month and three months.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이종수,윤태진,안진환,Jong Soo Lee, MD, PhD, Tae-Jin Yoon, MD, Jin Hwan Ahn, MD. (2009).구면렌즈 C-flex™(570C)와 비구면렌즈 C-flex™(970C)의 임상적 유용성의 비교. 대한안과학회지, 50 (10), 1514-1519

MLA

이종수,윤태진,안진환,Jong Soo Lee, MD, PhD, Tae-Jin Yoon, MD, Jin Hwan Ahn, MD. "구면렌즈 C-flex™(570C)와 비구면렌즈 C-flex™(970C)의 임상적 유용성의 비교." 대한안과학회지, 50.10(2009): 1514-1519

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제