본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

최대 운동부하시 종목별 운동선수들의 심폐기능 비교 연구

이용수 25

영문명
A Study on the Cardiovascular function by athletic Events of the maximal exercise loading
발행기관
경희대학교 스포츠과학연구원
저자명
최영근(Choi Young Keun) 박철빈(Park Chul Bin) 유승희(Yoo Seung Hee) 김복현(Kim Bok Hyeon) 심성섭(Sim Sung Sub)
간행물 정보
『체육학논문집』제22집, 159~170쪽, 전체 12쪽
주제분류
예술체육 > 체육
파일형태
PDF
발행일자
1994.12.01
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

  We investigated the difference of the cardiovascular function in order to hold the characteristics of athletic events to advance the contest capability.
  We acquired scientific data from cycle Ergometer with gradual incremental work load.
  By this research, we drawn a conclusion as follows.
  1. The maximal tidal volume was revealed as G2(3270.85±985.56㎖/min), followed by G1(3040.11±531.06㎖/min), followed by G4(2970.20±300.12㎖/min), followed by G5(2682.91±379.28㎖/min), followed by G3(2395.91±572.21 ㎖/min) and there is a remarkable difference between groups(P<0.01).
  2. The maximal ventilation(?<SUB>E</SUB> max) was recorded as G2(168.58±51.88l/min), followed by G4(156.29±17.99l/min), followed by G1(141.46±22.10l/min), followed by G5(134.29±16.45l/min), followed by G3(105.23±11.09/min) and also remarkable difference was found among groups(P<0.001).
  3. We could not found reliable difference the maximal respiration rate(RR) was located from G2(63.78±12.65n/min) to G3(57.55±7.92n/min).
  4. The maximal heart rate was appeared as G1(191.56±6.28beat/min), followed by G5(185.76±9.07beat/min), followed by G2(181.15±7.19beat/min), followed by G3(178.02±8.13beat/min), followed by G4(174.62±9.16beat/min) also there"s a remarkable difference was found (P<0.001).
  5. The maximal O2 pulse was record as order of G2(25.26±6.87), followed by G4(24.07±2.74), followed by G1(20.13±4.47), followed by G5(19.39±2.33), followed by G3(15.01±1.88) and showed reliable difference(P<0.001).
  6. The maximal oxygen uptake was record as order of G2(4315.45±1175.89㎖/min), followed by G4(4110.00±372.62㎖/min), followed by Gl(3556.58±412.24㎖/min), followed by G5.3(3442.45±335.09㎖/min), followed by G3(2604.91±242.88㎖/min) and showed reliable difference(P<0.001).
  7. The maximal ventilation of carbon dioxide(?CO₂) was record as order of G4(5877.69±728.60㎖/min), G2(5796.05±1582.40㎖/min), G1(4873.05±600.09㎖/min), G5(4497.95±569.49㎖/min), G3(3541.36±435.57㎖/min) and showed reliable difference(P<0.001).
  8. The maximal rate of gas exchange was record as order of G4(1.88±0.82) followed by G5(1.78±0.10) followed by G1(1.69±0.27) followed by G3(1.61±0.11) followed by G2(1.51±0.10) and showed reliable difference(P<0.05).
  9. The maximal oxygen uptake of maximal was appeared as G2(59.82±14.40㎖/㎏/min), followed by G4(52.39±4.13㎖/㎏/min), followed by G1(48.97±5.01㎖/㎏/min), followed by G5(46.23±2.89㎖/㎏/min), followed by G3(41.75±3.38㎖/㎏/min) also theres a remarkable difference was found (P<0.001).
  By above data we reached some conclusion as follows. Except for the respiration rate, the maximal value in the state of exercise revealed the reliable difference between those groups, and cardiovascular function was recorded as order of G2, G4, G1, G5, G3, but in case of gas exchange did not.

목차

ABSTRACT
Ⅰ. 서론
Ⅱ. 연구방법
Ⅲ. 연구결과 및 고찰
Ⅳ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최영근(Choi Young Keun),박철빈(Park Chul Bin),유승희(Yoo Seung Hee),김복현(Kim Bok Hyeon),심성섭(Sim Sung Sub). (1994).최대 운동부하시 종목별 운동선수들의 심폐기능 비교 연구. 체육학논문집, 22 , 159-170

MLA

최영근(Choi Young Keun),박철빈(Park Chul Bin),유승희(Yoo Seung Hee),김복현(Kim Bok Hyeon),심성섭(Sim Sung Sub). "최대 운동부하시 종목별 운동선수들의 심폐기능 비교 연구." 체육학논문집, 22.(1994): 159-170

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제