본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

안경사 임상 굴절검사에 대한 분석

이용수 41

영문명
Analysis for Clinical Refraction by Optometrists
발행기관
한국보건기초의학회
저자명
노재현 오광근 문병연 유동식 김상엽 조현국
간행물 정보
『한국보건기초의학회지』제15권 제2호, 135~139쪽, 전체 5쪽
주제분류
의약학 > 면역학
파일형태
PDF
발행일자
2022.12.31
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

A total 136 cases of refraction examinations performed between the year 2015 and 2018 by korean optometrists were analyzed based on 16 items to assess the errors observed during these examinations. The results of the analysis showed that history were not administered in 50.7% of the cases. Further, dominant eye testing was not performed in 72.8% of cases; uncorrected visual acuity testing in 86.8%; refractive power measurements of the current prescription in 54.4%; corrected visual acuity testing with the current prescription in 91.9%; subjective refraction test using a phoropter in 45.6%; fogging before refraction testing in 72.1%; maximal visual acuity testing in 80.9%; fogging before astigmatism testing in 72.8%; astigmatic fan chart testing in 49.3%; astigmatic refining testing in 39.0%; maintenance of meridian balance during astigmatic refining testing in 66.2%; binocular balance testing in 29.4%; and spherical end-point testing in 12.5%. The most preferred test for measuring binocular balance was the alternating cover test, which was performed in 27.4% of the cases, and the most preferred method to the measure end-point of refraction was the maximum plus to maximum visual acuity (MPMVA) procedure, performed in 43.4% of the cases. In 45.0% of the cases, optometrists performed the binocular balance test without the dominant eye test, and in 26.5% of cases, they conducted the astigmatic fan chart test without fogging. In 27.2% of the cases, astigmatic refining tests were conducted without the maintenance of the meridian balance; 23.5% of the binocular end-point refraction measurements were conducted without the binocular balance test, and 35.3% of astigmatic tests were conducted with unchanged autorefractometer (AR) values. Such inaccuracies during the examination process could lead to inability in obtaining a complete correction of the refractive errors in the participants and cause various deviations in the refraction test-based binocular visual function findings.

목차

서 론
연구 방법
연구 결과
고 찰
결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

노재현,오광근,문병연,유동식,김상엽,조현국. (2022).안경사 임상 굴절검사에 대한 분석. 한국보건기초의학회지, 15 (2), 135-139

MLA

노재현,오광근,문병연,유동식,김상엽,조현국. "안경사 임상 굴절검사에 대한 분석." 한국보건기초의학회지, 15.2(2022): 135-139

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제