Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구

이용수 0

영문명
Motion Reduction Activities in Patients undergoing Myocardial Perfusion SPECT with the Discovery NM 530c(D530c)
발행기관
대한핵의학기술학회
저자명
이동훈(Dong Hun Lee) 최우준(Woo Jun Choi) 정우영(Woo Young Jung)
간행물 정보
『핵의학기술』Vol.21 No.2, 80~85쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2017.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The D530c have cadmium zinc telluride(CZT) detectors that are arranged focus on the heart. This structural characteristic allows for quicker imaging without rotation, but this is sensitive to patient movement and can affect the test results. The aim of this study is to optimize the image quality by reducing patient movement during the examination. Materials and Methods We analyzed the patients’ movements, and performed various activities such as provided patient education about correct breathing techniques and avoiding patient movements, and created breathing correction tools to minimize patient movement during exam. The 70 patients who underwent myocardial perfusion SPECT with D530c in November 2016 were categorized as the group before the corrective steps. Another 70 patients who underwent the procedure with D530c from February 14, 2017 to February 21, 2017 were categorized as the improvement group. Images acquired during stress and at rest were compared and analyzed by measuring the durations of heart movements over certain distances (4 mm, 8 mm, 12 mm, or more) noted on the x-, y-, and zaxes. Results After the activities, the durations of heart movements decreased in the images acquired both under stress and at rest. In particular, there were no large motions greater than 12 mm recorded in the stress images after the improvement. There was a significant difference (p<0.005) in the 4-mm and 8-mm fluctuations on the X-axis and the 8-mm fluctuations on the Z axis in the stress images, but there was no significant difference (p>0.005) in the other stress and rest intervals. Conclusion The decrease in the time of motion occurrence due to the 4 mm fluctuation distance that can occur through breathing can be understood as a result of the breathing being corrected through training and motion prevention tools. It is expected that the image quality will be improved by reducing the occurrence time according to the variation distance of 8 mm or 12 mm, which is expected as the actual movement of the patient other than the breathing.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이동훈(Dong Hun Lee),최우준(Woo Jun Choi),정우영(Woo Young Jung). (2017).Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구. 핵의학기술, 21 (2), 80-85

MLA

이동훈(Dong Hun Lee),최우준(Woo Jun Choi),정우영(Woo Young Jung). "Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구." 핵의학기술, 21.2(2017): 80-85

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제