학술논문
Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가
이용수 2
- 영문명
- The Evaluation of Quantitative Accuracy According to Detection Distance in SPECT/CT Applied to Collimator Detector Response(CDR) Recovery
- 발행기관
- 대한핵의학기술학회
- 저자명
- 김지현(Ji-Hyeon Kim) 손현수(Hyeon-Soo Son) 이주영(Juyoung Lee) 박훈희(Hoon-Hee Park)
- 간행물 정보
- 『핵의학기술』Vol.21 No.2, 55~64쪽, 전체 10쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2017.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Recently, with the spread of SPECT/CT, various image correction methods can be applied quickly and accurately, which enabled us to expect quantitative accuracy as well as image quality improvement. Among them, the Collimator Detector Response(CDR) recovery is a correction method aiming at resolution recovery by compensating the blurring effect generated from the distance between the detector and the object. The purpose of this study is to find out quantitative change depending on the change in detection distance in SPECT/CT images with CDR recovery applied. Materials and Methods In order to find out the error of acquisition count depending on the change of detection distance, we set the detection distance according to the obit type as X, Y axis radius 30cm for circular, X, Y axis radius 21cm, 10cm for non-circular and non-circular auto(=auto body contouring, ABC_spacing limit 1cm) and applied reconstruction methods by dividing them into Astonish(3D-OSEM with CDR recovery) and OSEM(w/o CDR recovery) to find out the difference in activity recovery depending on the use of CDR recovery. At this time, attenuation correction, scatter correction, and decay correction were applied to all images. For the quantitative evaluation, calibration scan(cylindrical phantom, ⁹⁹ᵐTcO₄ 123.3 MBq, water 9293 ml) was obtained for the purpose of calculating the calibration factor(CF). For the phantom scan, a 50 cc syringe was filled with 31 ml of water and a phantom image was obtained by setting ⁹⁹ᵐTcO₄ 123.3 MBq. We set the VOI(volume of interest) in the entire volume of the syringe in the phantom image to measure total counts for each condition and obtained the error of the measured value against true value set by setting CF to check the quantitative accuracy according to the correction. Results The calculated CF was 154.28 (Bq/ml/cps/ml) and the measured values against true values in each conditional image were analyzed to be circular 87.5%, non-circular 90.1%, ABC 91.3% and circular 93.6%, non-circular 93.6%, ABC 93.9% in OSEM and Astonish, respectively. The closer the detection distance, the higher the accuracy of OSEM, and Astonish showed almost similar values regardless of distance. The error was the largest in the OSEM circular(-13.5%) and the smallest in the Astonish ABC(-6.1%). Conclusion SPECT/CT images showed that when the distance compensation is made through the application of CDR recovery, the detection distance shows almost the same quantitative accuracy as the proximity detection even under the distant condition, and accurate correction is possible without being affected by the change in detection distance.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
Reference
해당간행물 수록 논문
- 의료용 방사성폐기물 자체처분 가이드라인에 관한 고찰
- Collimator Detector Response(CDR) 회복이 적용된 SPECT/CT에서 검출거리에 따른 정량적 정확성 평가
- 3D 프린팅 팬텀의 핵의학분야 적용 평가
- 여성 핵의학 방사선종사자의 관련 피폭요인 분석
- Estradiol 검사 시 방사성 추적자의 희석시간에 대한 고찰
- 방사성 요오드 치료 후, 퇴원 선량 측정에 있어 각국의 기준 및 권고 비교
- Discovery NM 530c(D530c)에서 촬영한 심근관류 SPECT 환자의 움직임 감소활동을 위한 연구
- 뇌척수액에서 항 Glutamic acid decarboxylase 항체검사의 참고치 설정
- PET/CT 검사에서 Q.Clear 기법의 유용성에 대한 고찰
- Article PET/CT 감쇠보정시 다양한 CT Kernel 적용에 따른 유용성 평가
- 양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!