본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증

이용수 0

영문명
The Effect of PET Scan Time on the Off-Line PET Image Quality in Proton Therapy
발행기관
대한핵의학기술학회
저자명
홍건철(Gun-Chul Hong) 장준영(Joon-Yung Jang) 박세준(Se-Joon Park) 차은선(Eun-Sun Cha) 이혁(Hyuk Lee)
간행물 정보
『핵의학기술』Vol.21 No.2, 74~79쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2017.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Proton therapy can deliver an optimal dose to tumor while reducing unnecessary dose to normal tissue as compared the conventional photon therapy. As proton beams are irradiated into tissue, various positron emitters are produced via nuclear fragmentation reactions. These positron emitters could be used for the dose verification by using PET. However, the short half-life of the radioisotopes makes it hard to obtain the enough amounts of events. The aim of this study is to investigate the effect of off-line PET imaging scan time on the PET image quality. Materials and Methods The various diameters of spheres (D=37, 28, 22 ㎜) filled with distilled water were inserted in a 2001 IEC body phantom. Then proton beams (100 MU) were irradiated into the center of the each sphere using the wobbling technique with the gantry angle of 0°. The modulation widths of the spread out bragg peak were 16.4, 14.7 and 9.3 cm for the spheres of 37, 28 and 22 ㎜ in diameters respectively. After 5 min of the proton irradiation, the PET images of the IEC body phantom were obtained for 50 min. The PET images with different time courses (0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min) were obtained by dividing the frame with a duration of 10 min. In order to evaluate the off-line PET image quality with the different time courses, the contrast-to-noise ratio (CNR) of the PET image calculated for each sphere. Results The CNRs of the sphere (D=37 ㎜) were 0.43, 0.42, 0.40, 0.31 and 0.21 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNRs of the sphere (D=28 ㎜) were 0.36, 0.32, 0.27, 0.19 and 0.09 for the time courses of 0-10 min, 11-20 min, 21-30 min, 31-40 min and 41-50 min respectively. The CNR of 37 ㎜ sphere was decreased rapidly after 30 min of the proton irradiation. In case of the spheres of 28 ㎜ and 22 ㎜, the CNR was decreased drastically after 20 min of the irradiation. Conclusion The off-line PET imaging time is an important factor for the monitoring of the proton therapy. In case of the lesion diameter of 22 ㎜, the off-line PET image should be obtained within 25 min after the proton irradiation. When it comes to small size of tumor, the long PET imaging time will be beneficial for the proton therapy treatment monitoring.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

홍건철(Gun-Chul Hong),장준영(Joon-Yung Jang),박세준(Se-Joon Park),차은선(Eun-Sun Cha),이혁(Hyuk Lee). (2017).양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증. 핵의학기술, 21 (2), 74-79

MLA

홍건철(Gun-Chul Hong),장준영(Joon-Yung Jang),박세준(Se-Joon Park),차은선(Eun-Sun Cha),이혁(Hyuk Lee). "양성자 치료에서 영상 획득 시간에 따른 Off Line PET의 효율성 검증." 핵의학기술, 21.2(2017): 74-79

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제