본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Insulin 측정용 방사면역측정법 시약의 평가

이용수 0

영문명
The Evaluation of Radioimmunoassay kits for Insulin
발행기관
대한핵의학기술학회
저자명
신용환(Yong Hwan Shin) 김윤현(Yun Hyun Kim) 이일규(Il Kyu Lee) 김지영(Ji Young Kim) 석재동(Jae Dong Seok) 신숙희(Suk Hee Shin)
간행물 정보
『핵의학기술』Vol.16 No.2, 149~155쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : Serum insulin levels are useful indicator which of reflecting the function of insulin secretion in pancreatic β cell and diagnosis of diabetes, differentiating the cause of impaired glucose tolerance. Insulin measurement kits have shown some differences in many ways such as test methods as well as quality control. The purpose of this study was to evaluate the diagnostic performance of seven manufacturing companies commercial kits. Materials and Methods : The values of insulin measured by three manufacturing companies (Biosource, Siemens, TFB) with 59 samples in August 2009 were compared with those measured by four manufacturing companies (Immunotech, Izotope, BNIBT, Cisbio) with 68 samples in December 2011. We evaluated precision, recovery rate, dilution test and correlation of serum insulin measurement using seven manufacturing company kits. Statistical program SPSS 12.0 was used for the verification of results. Results : The coefficients variation of the precision on all seven different kits were showed within 5.0%. Recovery rate of Biosource, Siemens, TFB kits on three different levels showed 94.2~103.7%, 99.0~104.6%, 99.7~ 107.6% respectively. Immunotech, Izotope, BNIBT, Cisbio were 93.5~99.1%, 91.4~99.1%, 99.2~131.0%, 84.8~102.3% respectively. There was strong correlation between the measurement of insulin by Biosource kit and that by two commercial kits, Siemens (R2=0.96), TFB (R2=0.99). There was good correlation between the measurement of insulin by TFB kit and that by three commercial kits, Immunotech (R2=0.97), Izotope (R2=0.96), Cisbio (R2=0.97). In the dilution test performed with more than 200 μIU/ml high concentration samples, samples with diabetes correctly was measured in all seven manufacturing kits. However, as measured with insulinoma samples TFB, Siemens, Izotope, Cisbio kits were correctly measured , but Biosource and Immunotech kits were measured 47.4 μIU/ml, 72.3 μIU/ml, respectively. Conclusion : Serum Insulin radioimmunoassay kits were showed excellent precision, correlation and good recovery rate. However, some kits were not measured correctly in the high concentration insulin values. when selecting a kit should be considered many factors that cost effectiveness, compatible for automation equipment, high performance kit, the environment for each laboratory such as reaction time and reporting time.

목차

서론
대상 및 방법
결과
연구의 제한
고찰 및 결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

신용환(Yong Hwan Shin),김윤현(Yun Hyun Kim),이일규(Il Kyu Lee),김지영(Ji Young Kim),석재동(Jae Dong Seok),신숙희(Suk Hee Shin). (2012).Insulin 측정용 방사면역측정법 시약의 평가. 핵의학기술, 16 (2), 149-155

MLA

신용환(Yong Hwan Shin),김윤현(Yun Hyun Kim),이일규(Il Kyu Lee),김지영(Ji Young Kim),석재동(Jae Dong Seok),신숙희(Suk Hee Shin). "Insulin 측정용 방사면역측정법 시약의 평가." 핵의학기술, 16.2(2012): 149-155

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제