갑상선암 수술 전 진단목적의 ¹⁸F-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가

이용수 0

영문명
The Preoperative Diagnosis of Thyroid Cancer in ¹⁸F-FDG PET/CT Dual Time Imaging of SUV and Evaluation of Radioactivity Measurement
발행기관
대한핵의학기술학회
저자명
이현국(Hyun-Kuk Lee) 강현수(Hyun Soo Khang) 양승오(Seoung-Oh Yang) 한만석(Man-Seok Han)
간행물 정보
『핵의학기술』Vol.16 No.2, 99~105쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : This study is designed to compare two parameters reflecting ¹⁸F-FDG uptake, SUV and radioactivity, for diagnosis of thyroid cancer in dual time ¹⁸F-FDG PET/CT imaging and to find which parameter is more useful to decide whether the tumor is malignant or not. Materials and Methods : We performed retrospective study for 40 patients. All patients are diagnosed as primary thyroid cancer and examined ¹⁸F-FDG PET/CT. First, we got the dispersion of scattering beam of neck and lung apex to set a background and compared each dispersion, mean value, standard deviation of maxSUV and radioactivity. Also, mean maxSUV, △maxSUV, △ maxBq/ml(%) and radioactivity between groups according to lesion's size based on biopsy are compared with independent-sample t-test. Results : the values that were from maxSUV and radioactivity measurement technique were compensated and calculated to practical values for mean comparison and patients were divided to two groups based on tumor size, Group1 (size≤1 cm, n=21), Group2 (size>1 cm, n=19) for accurate comparison. In Group1, maxSUV (semi-quantitative analysis) was increased from 5.64±5.85 (1.89~17.84) at first image to 5.90±5.01 (1.95~18.22) at second image and radioactivity (Bq/ml) (quantitative analysis) showed similar increase from 5.93±6.38 (2.50~16.75) at first image to 6.01±5.25 (2.66~16.58) at second image. In Group2, TFmaxSUV was 10.54±14.36 (2.54~33.89) in true first image, TSmaxSUV was 9.85±12.88 (2.62~26.20) in true second image separately. The maxSUV showed a significant difference in the mean comparison between the two groups (p=0.035) But, mean radioactivity (Bq/ml) was 5.93±6.38 (4.81~40.99) in true first image, 6.01±5.25 (4.51~36.93) in true second image and didn't show a significant difference statistically (p=0.126) Conclusion : In diagnosis of thyroid tumor, SUV and radioactivity depending on ¹⁸F-FDG uptake showed high similarity with coefficient of determination (R2=0.939) and malignant evaluation results using dual time also showed similar aspect. Radioactivity for evaluation of malignant tumor didn't show better specificity or sensitivity than maxSUV.

목차

서론
대상 및 방법
결과
고찰
결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이현국(Hyun-Kuk Lee),강현수(Hyun Soo Khang),양승오(Seoung-Oh Yang),한만석(Man-Seok Han). (2012).갑상선암 수술 전 진단목적의 ¹⁸F-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가. 핵의학기술, 16 (2), 99-105

MLA

이현국(Hyun-Kuk Lee),강현수(Hyun Soo Khang),양승오(Seoung-Oh Yang),한만석(Man-Seok Han). "갑상선암 수술 전 진단목적의 ¹⁸F-FDG PET/CT Dual Time Point영상에서 SUV값과 방사능 농도 측정법의 유용성 평가." 핵의학기술, 16.2(2012): 99-105

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제