Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구

이용수 0

영문명
The Study on Usefulness of LEAP Collimator in Lung Ventilation SPECT
발행기관
대한핵의학기술학회
저자명
김정수(Jung Soo Kim) 김수미(Soo Mee Kim) 김진의(Jin Eui Kim) 이재성(Jae Sung Lee) 이동수(Dong Soo Lee)
간행물 정보
『핵의학기술』Vol.16 No.2, 18~24쪽, 전체 7쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : Although lung ventilation SPECT (LV-SPECT) has a good sensitivity in detection of deep lung lesions, it is difficult to apply the LV-SPECT to patients having breathing problems due to limited examination time. In this study, we evaluated the usefulness of LEAP collimator, which provides high detection sensitivity and tolerable resolution, for the LV-SPECT in terms of diagnostic accuracy and examination time. Materials and Methods : Four volunteers inhaled Technegas (370 MBq) and the lung ventilation planar scan (LVPS, 300 counts/view (cpv)) with LEHR collimator was performed using Siemens E.cam scanner as a reference test. LV-SPECT scans were performed with three collimators, LEHR, LEUHR, and LEAP, in low (7 kcpv) and high (70 kcpv) counting modes. The count ratios of left (LT) and right (RT) lung segments were calculated on the geometric mean view of anterior and posterior images for LVPS and on the summed coronal images of LV-SPECT, respectively. Comparing to LVPS, the usefulness of three different collimators for LV-SPECT was evaluated through statistical analysis (paired t-test), on count ratios of lung segments. Results : The average LT:RT ratio in LVPS was 47:53. For LV-SPECT, there were negligible difference of the LT:RT ratios (48:52 on average) among three different collimators in low and high counting modes. Comparing to standard LVPS with LEHR, all LV-SPECTs with different collimators resulted in similar diagnostic accuracy through paired t-test (p>0.05). The scan time in LVPS (6 views) was 17.3 min. For LV-SPECT (128 views) in low counting mode, it took 18.7 (LEUHR), 15.0 (LEHR), and 12.3 min (LEAP), respectively. Conclusion : Comparing to standard LVPS, the LV-SPECT with LEAP in low counting mode provided the comparable diagnostic accuracy in addition to shortened scan time.

목차

서론
실험재료 및 방법
결과
고찰
추후과제
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김정수(Jung Soo Kim),김수미(Soo Mee Kim),김진의(Jin Eui Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). (2012).Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구. 핵의학기술, 16 (2), 18-24

MLA

김정수(Jung Soo Kim),김수미(Soo Mee Kim),김진의(Jin Eui Kim),이재성(Jae Sung Lee),이동수(Dong Soo Lee). "Lung Ventilation SPECT에서 LEAP Collimator의 유용성에 관한 연구." 핵의학기술, 16.2(2012): 18-24

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제