본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

¹⁸F-FDG PET 영상의 정량적 비교

이용수 0

영문명
Quantitative Comparisons in ¹⁸F-FDG PET Images: PET/MR VS PET/CT
발행기관
대한핵의학기술학회
저자명
이무석(Moo Seok Lee) 임영현(Young Hyun Im) 김재환(Jae hwan Kim) 최규오(Gyu O Choe)
간행물 정보
『핵의학기술』Vol.16 No.2, 68~80쪽, 전체 13쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2012.10.30
4,360

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : More recently, combined PET/MR scanners have been developed in which the MR data can be used for both anatometabolic image formation and attenuation correction of the PET data. For quantitative PET information, correction of tissue photon attenuation is mandatory. The attenuation map is obtained from the CT scan in the PET/CT. In the case of PET/MR, the attenuation map can be calculated from the MR image. The purpose of this study was to assess the quantitative differences between MR-based and CT-based attenuation corrected PET images. Materials and Methods : Using the uniform cylinder phantom of distilled water which has 199.8 MBq of ¹⁸F-FDG put into the phantom, we studied the effect of MR-based and CT-based attenuation corrected PET images, of the PET-CT using time of flight (TOF) and non-TOF iterative reconstruction. The images were acquired from 60 minutes at 15-minute intervals. Region of interests were drawn over 70% from the center of the image, and the Scanners' analysis software tools calculated both maximum and mean SUV. These data were analyzed by one way-anova test and Bland-Altman analysis. MR images are segmented into three classes(not including bone), and each class is assigned to each region based on the expected average attenuation of each region. For clinical diagnostic purpose, PET/MR and PET/CT images were acquired in 23 patients (Ingenuity TF PET/MR, Gemini TF64). PET/CT scans were performed approximately 33.8 minutes after the beginnig of the PET/MR scans. Region of interests were drawn over 9 regions of interest(lung, liver, spleen, bone), and the Scanners' analysis software tools calculated both maximum and mean SUV. The SUVs from 9 regions of interest in MR-based PET images and in CT-based PET images were compared. These data were analyzed by paired t test and Bland-Altman analysis. Results : In phantom study, MR-based attenuation corrected PET images generally showed slightly lower -0.36~-0.15 SUVs than CT-based attenuation corrected PET images (p <0.05). In clinical study, MR-based attenuation corrected PET images generally showed slightly lower SUVs than CT-based attenuation corrected PET images (excepting left middle lung and transverse Lumbar) (p<0.05). And percent differences were -8.0~1.79% lower for the PET/MR images than for the PET/CT images. (excepting lung) Based on the Bland-Altman method, the agreement between the two methods was considered good. Conclusion : PET/MR confirms generally lower SUVs than PET/CT. But, there were no difference in the clinical interpretations made by the quantitative comparisons with both type of attenuation map.

목차

서론
실험재료 및 방법
결과
고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이무석(Moo Seok Lee),임영현(Young Hyun Im),김재환(Jae hwan Kim),최규오(Gyu O Choe). (2012).¹⁸F-FDG PET 영상의 정량적 비교. 핵의학기술, 16 (2), 68-80

MLA

이무석(Moo Seok Lee),임영현(Young Hyun Im),김재환(Jae hwan Kim),최규오(Gyu O Choe). "¹⁸F-FDG PET 영상의 정량적 비교." 핵의학기술, 16.2(2012): 68-80

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제