접촉식과 광학적 방식에 의한 전방깊이 측정값의 비교

이용수 0

영문명
Comparison of Anterior Chamber Depth Obtained from Applanation and Optical Principle Devices
발행기관
대한안과학회
저자명
박율리 황형빈 정성근,Yuli Park, MD, Hyung Bin Hwang, MD, Sung Kun Chung, MD, PhD
간행물 정보
『대한안과학회지』Ophthalmological Society,volume54,number8, 1219~1226쪽, 전체 8쪽
주제분류
의약학 > 기타의약학
파일형태
PDF
발행일자
2013.08.15
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: To assess the reproducibility and reliability of applanation A-scan ultrasonography (Pacscan 300A, Sonomed Inc., Chicago, IL, USA) and optical measurements with IOL Master® (Carl Zeiss Meditec, Germany), Pentacam® (Oculus, Wetzlar, Germany), and Orbscan II® (Orbtek Inc., Laredo, TX, USA) when measuring anterior chamber depth (ACD). Methods: In this study of 188 eyes of 94 patients, ACD estimation prior to cataract surgery was preformed by the applanation A-scan method and IOL Master®, Pentacam®, and Orbscan II® optical methods. Repeatability from each device was evaluated by coefficient of variation, standard deviation, and intraclass correlation coefficient. RM-ANOVA on Ranks was used to compare the differences in ACD among the devices. The Bland-Altman plot was performed to assess agreement in measurements between the devices. Results: The mean ACD according to the applanation A-scan method and IOL Master®, Pentacam®, and Orbscan II® optical methods were 2.89 ± 0.49 mm, 3.25 ± 0.45 mm, 3.21 ± 0.46 mm, and 3.19 ± 0.47 mm, respectively, and the differences were statistically significant (p < 0.01). The coefficient of variation for the 4 methods was 2.50% in the A-scan, 0.87% in the IOL Master®, 1.25% in the Pentacam®, and 1.04% with Orbscan II®, and reproducibility was higher with the optical principle devices. The correlation coefficient between A-scan and IOL Master® was 0.65, between IOL Master® and Pentacam® 0.91, between IOL Master® and Orbscan II® 0.90, between A-scan and Pentacam® 0.69, between A-scan and Orbscan II® 0.71, and between Pentacam® and Orbscan II® 0.93. Conclusions: Applanation A-scan provided lower measurements for ACD compared with IOL Master®, Pentacam® and Orbscan II®. There was good agreement between results obtained with the latter 3 methods, and reproducibility was high with optical measurements. The coefficient of variation was low for IOL Master®.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박율리,황형빈,정성근,Yuli Park, MD, Hyung Bin Hwang, MD, Sung Kun Chung, MD, PhD. (2013).접촉식과 광학적 방식에 의한 전방깊이 측정값의 비교. 대한안과학회지, 54 (8), 1219-1226

MLA

박율리,황형빈,정성근,Yuli Park, MD, Hyung Bin Hwang, MD, Sung Kun Chung, MD, PhD. "접촉식과 광학적 방식에 의한 전방깊이 측정값의 비교." 대한안과학회지, 54.8(2013): 1219-1226

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제