본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계

이용수 10

영문명
Relationship between Oxygen Uptake and Cardiac Output on Maximal Treadmill Exercise in Marathoners by Improved Impedance Cardiography
발행기관
대한생리학회
저자명
강두희(Kang, Doo-Hee) 황수관(Hwang, Soo-Kwan) 연동수(Yeon, Dong-Soo) 유선희(Yuh, Seon-Hee) 김덕원(Kim, Deok-Won)
간행물 정보
『대한생리학회지』제24권 제2호, 249~260쪽, 전체 12쪽
주제분류
의약학 > 의학일반
파일형태
PDF
발행일자
1990.12.31
4,240

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Maximal cardiac output and oxygen uptake (VO2max) were measured during treadmill exercise for seven top-class marathoners and nine non-athletes using impedance cardiograph developed by one of the authors (DW Kim). Results of this study are summarized as belows. 1) New shoes with sponge and silicon rubber attached to the soles were developed to reduce motion artifact during treadmill exercise. Ensemble everaging techneque with the developed shoes was also used to improve the measurement of stroke volume using impedance cardiography. 2) Maximal cardiac output of the athletes, 14.98 L/min, was significantly higher than that of the non-athletes, 13.46 L/min. As maximal heart rate of the marathoners is lower than that of non-athletes, stroke volume of the former is significantly larger than that of the latter. 3) (VO2max) of the marathoners, 59.38 ml/kg/min, was higher than that of the non-athletes, 40.22 ml/kg/min. At the anaerobic threshold. (VO2max) of the former was 62.3% of (VO2max) and this was significantly higher than that of the non-athletes, 57.2%, This results indicates that the marathoners have higher aerobic capacity than the non-athletes. 4) The marathoners showed larger VO2 than the non-athletes at the same cardiac output, indicating that a-v O2 of the former is higher than that of the latter. 5) Maximal systolic pressure of the marathoners was higher than that of the non-athletes, and so was maximal rate-pressure products. These results indicate that heart oxygen consumption rate (hVO2) of the marathoner is higher than that of the non-athletes is mainly due to higher stroke volume. And higher oxygen consumption of the marathoners is due to higher stroke volume. And higher oxygen consumption of the marathoners is due to their larger a-v O2. The marathoners show both higher threshold and (VO2max). Especially, measurement of cardiac output during treadmill exercise by improved impedance cardiography is expected to contribute in study of cardiac function of athletes.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

강두희(Kang, Doo-Hee),황수관(Hwang, Soo-Kwan),연동수(Yeon, Dong-Soo),유선희(Yuh, Seon-Hee),김덕원(Kim, Deok-Won). (1990).Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계. 대한생리학회지, 24 (2), 249-260

MLA

강두희(Kang, Doo-Hee),황수관(Hwang, Soo-Kwan),연동수(Yeon, Dong-Soo),유선희(Yuh, Seon-Hee),김덕원(Kim, Deok-Won). "Treadmill 최대 운동시 Impedance 심장기록법의 개선에 의한 마라톤 선수의 심박출량과 산소소비량과의 관계." 대한생리학회지, 24.2(1990): 249-260

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제