동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰

이용수 0

영문명
An Optimization Method of Measuring Heart Position in Dynamic Myocardial Perfusion SPECT with a CZT-based camera
발행기관
대한핵의학기술학회
저자명
성지혜(Ji Hye Seong) 이동훈(Dong Hun Lee) 김은혜(Eun Hye Kim) 정우영(Woo Young Jung)
간행물 정보
『핵의학기술』Vol.23 No.1, 75~79쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2019.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Cadmium-zinc-telluride (CZT) camera with semiconductor detector is capable of dynamic myocardial perfusion SPECT for coronary flow reserve (CFR). Image acquisition with the heart positioned within 2 cm in the center of the quality field of view (QFOV) is recommended because the CZT detector based on focused multi-pinhole collimators and is stationary gantry without rotation. The aim of this study was to investigate the optimal method for measuring position of the heart within the center of the QFOV when performing dynamic myocardial perfusion SPECT with the Discovery NM 530c camera. Materials and Methods From June to September 2018, 45 patients were subject to dynamic myocardial perfusion SPECT with D530c. For accurate heart positioning, the patient's heart was scanned with a mobile ultrasound and marked at the top of the probe where the mitral valve (MV) was visible in the parasternal long-axis view (PLAX). And, the marked point on the patient's body matched with the reference point indicated CZT detector in dynamic stress. The heart was positioned to be in the center of the QFOV in rest. The coordinates of dynamic stress and rest were compared statistically. Results The coordinates of the dynamic stress using mobile ultrasound and those taken of the rest were recorded for comparative analysis with regard to the position of the couch and analyzed. There were no statistically significant differences in the coordinates of Table in & out, Table up & down, and Detector in & out (P > 0.05). The difference in distance between the 2 groups was measured at 0.25 ± 1.00, 0.24 ± 0.96 and 0.25 ± 0.82 cm respectively, with no difference greater than 2 cm in all categories. Conclusion The position of the heart taken using mobile ultrasound did not differ significantly from that of the center of the QFOV. Therefore, The use of mobile ultrasound in dynamic stress will help to select the correct position of the heart, which will be effective in clinical diagnosis by minimizing the image quality improvement and the patient's exposure to radiation.

목차

서론
실험재료 및 방법
결과
결론
요약
REFERENCE

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

성지혜(Ji Hye Seong),이동훈(Dong Hun Lee),김은혜(Eun Hye Kim),정우영(Woo Young Jung). (2019).동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰. 핵의학기술, 23 (1), 75-79

MLA

성지혜(Ji Hye Seong),이동훈(Dong Hun Lee),김은혜(Eun Hye Kim),정우영(Woo Young Jung). "동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰." 핵의학기술, 23.1(2019): 75-79

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제