학술논문
Technegas를 이용한 폐환기 검사와 폐기능 검사의 상관관계에 관한 고찰
이용수 0
- 영문명
- A Study on the Correlation between Lung Ventilation Scan using Technegas and Pulmonary Function Test in Patients with COPD
- 발행기관
- 대한핵의학기술학회
- 저자명
- 김상규(Sang-Gyu Kim) 김진구(Jin-Gu Kim) 백송이(Song-EE Baek) 강천구(Chun-Koo Kang) 김재삼(Jae-Sam Kim)
- 간행물 정보
- 『핵의학기술』Vol.23 No.1, 45~49쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2019.04.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Lung Ventilation Scan(LVS) images directly inhaled radiation gas to evaluate lung ventilation ability. Therefore, it is influenced by various factors related to inhalation, including number of breaths, respiratory duration, respiration rate, and breathing method. In actual LVS examinations, it is difficult for objectify the patient's ability to inhale, and there is currently no known index related to inhalation. Therefore, this study confirms the correlation between counts per second(cps) in LVS and the results of pulmonary function test(PFT) and evaluate its usefulness as an objective indicator of inhalation. Materials and Methods From October 2010 to September 2018, 36 Chronic Obstructive Pulmonary Disease(COPD) patients who had both LVS and PFT were classified by severity(Mild, Moderate, Severe). LVS was performed by creating Technegas with Vita Medical's Technegas Generator and inhaling it to the patient. LVS images were acquired with Philips's Forte equipment., and PFT used Carefusion's Vmax Encore 22. The correlation between the cps measured by setting the region of interest(ROI) of both lungs on the LVS and the forced vital capacity(FVC), forced expiratory volume in one second(FEV1), FEV1/FVC of the results of PFT was compared and analyzed. Results We analyzed the correlation between cps of LVS using Technegas and the results of PFT by classifying COPD patients according to severity. Correlation coefficient between FEV1/FVC and cps was Severe -0.773, Moderate -0.750, and Mild -0.437. The Severe and Modulate result values were statistically significant(P<0.05) and Mild was not significant(P=0.155). On the other hand, the correlation coefficient between FVC and cps was statistically significant only in Mild and it was 0.882(P<0.05). Conclusion According to the study, we were able to analyze correlation between cps of LVS using Technegas and the results of PFT in COPD Patients. Using this result, when performing a LVS, the results of PFT can be used as an index of inhaling capacity. In addition, it is thought that it will be more effective for the operation of the exam rooms.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- 검사 안내문의 시각적 디자인화가 환자의 검사 이해도 및 정확성에 미치는 영향 평가
- 신장과 체중의 변화가 사구체 여과율에 미치는 영향
- 항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석
- Y-90 microsphere 로부터 생성되는 제동복사선의 차폐를 위한 차폐체 개발 연구
- PET/CT 검사 시 호흡에 따른 영상 왜곡 감소를 위한 엎드린 자세의 유용성 평가
- 18F-FDOPA Brain PET/CT 검사의 영상 대조도 분석 및 섭취 시간에 따른 SUV변화 고찰
- 핵의학 영상 검사의 중장기 추세 분석
- Technegas를 이용한 폐환기 검사와 폐기능 검사의 상관관계에 관한 고찰
- 고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가
- N-13 암모니아 주사액 제조 시 멸균필터의 흡착율 차이에 관한 비교 평가
- 동적 심근관류 SPECT에서 심장의 위치 측정방법에 대한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 핵의학 갑상샘 팬텀 영상에서 보간법이 초고분해능 ResNet 모델성능에 미치는 영향에 관한 연구
- 방사성동위원소(RI) 폐기물 내 Pb-214, Bi-214 화학 분리를 통한 핵종분석 방법에 관한 연구
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!