학술논문
용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험
이용수 0
- 영문명
- Pipetting Stability and Improvement Test of the Robotic Liquid Handling System Depending on Types of Liquid
- 발행기관
- 대한핵의학기술학회
- 저자명
- 백향미(Hyangmi Back) 김영산(Youngsan Kim) 윤선희(Sunhee Yun) 허의성(Uisung Heo) 김호신(Hosin Kim) 류형기(Hyeonggi Ryu) 이귀원(Guiwon Lee)
- 간행물 정보
- 『핵의학기술』Vol.20 No.2, 62~68쪽, 전체 7쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2016.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose In a cyclosporine experiment using a robotic liquid handing system has found a deviation of its standard curve and low reproducibility of patients's results. The difference of the test is that methanol is mixed with samples and the extractions are used for the test. Therefore, we assumed that the abnormal test results came from using methanol and conducted this test. In a manual of a robotic liquid handling system mentions that we can choose several setting parameters depending on the viscosity of the liquids being used, the size of the sampling tips and the motor speeds that you elect to use but there's no exact order. This study was undertaken to confirm pipetting ability depending on types of liquids and investigate proper setting parameters for the optimum dispensing ability. Materials and Methods 4types of liquids(water, serum, methanol, PEG 6000(25%)) and TSH¹²⁵I tracer(515 kBq) are used to confirm pipetting ability. 29 specimens for Cyclosporine test are used to compare results. Prepare 8 plastic tubes for each of the liquids and with multi pipette 400 ㎕ of each liquid is dispensed to 8 tubes and 100 ㎕ of TSH¹²⁵I tracer are dispensed to all of the tubes. From the prepared samples, 100 ㎕ of liquids are dispensed using a robotic liquid handing system, counted and calculated its CV(%) depending on types of liquids. And then by adjusting several setting parameters(air gap, dispense time, delay time) the change of the CV(%)are calcutated and finds optimum setting parameters. 29 specimens are tested with 3 methods. The first(A) is manual method and the second(B) is used robotic liquid handling system with existing parameters. The third(C) is used robotic liquid handling system with adjusted parameters. Pipetting ability depending on types of liquids is assessed with CV(%). On the basis of (A), patients's test results are compared (A)and(B), (A)and(C) and they are assessed with %RE(%Relative error) and %Diff(%Difference). Results The CV(%) of the CPM depending on liquid types were water 0.88, serum 0.95, methanol 10.22 and PEG 0.68. As expected dispensing of methanol using a liquid handling system was the problem and others were good. The methanol's dispensing were conducted by adjusting several setting parameters. When transport air gap 0 was adjusted to 2 and 5, CV(%) were 20.16, 12.54 and when system air gap 0 was adjusted to 2 and 5, CV(%) were 8.94, 1.36. When adjusted to system air gap 2, transport air gap 2 was 12.96 and adjusted to system air gap 5, Transport air gap 5 was 1.33. When dispense speed was adjusted 300 to 100, CV(%) was 13.32 and when dispense delay was adjusted 200 to 100 was 13.55. When compared (B) to (A), the result increased 99.44% and %RE was 93.59%. When compared (C-system air gap was adjusted 0 to 5) to (A), the result increased 6.75% and %RE was 5.10%. Conclusion Adjusting speed and delay time of aspiration and dispense was meaningless but changing system air gap was effective. By adjusting several parameters proper value was found and it affected the practical result of the experiment. To optimize the system active efforts are needed through the test and in case of dispensing new types of liquids proper test is required to check the liquid is suitable for using the equipment.
목차
서론
실험재료 및 방법
결과
결론 및 고찰
요약
REFERENCES
해당간행물 수록 논문
- Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가
- 성조숙증 여아들의 임상적 특징 및 진단별 성선자극호르몬 분비호르몬 GnRH (Gonado Tropin Releasing Hormone) 검사결과의 비교분석평가
- PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰
- 감시림프절 검사 시 입자크기에 따른 대체 방사성의약품의 유용성평가
- 범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구
- TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가
- ¹⁸F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법
- Excel의 추세선을 이용한 표준곡선 검증
- 비뇨기암 환자에서 ¹¹C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용
- 소아 ⁹⁹ᵐTc-DMSA renal scan에서 방광차폐유무와 방사성 동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구
- 핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가
- PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가
- 용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험
- PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- Attention UNet 모델을 활용한 유방 초음파 영상 분할: IoU 기반 학습 및 AUC, MSE 평가
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 삼중수소 측정 신뢰성 검증을 위한 국제숙련도시험 결과 평가
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!