본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

소아 ⁹⁹ᵐTc-DMSA renal scan에서 방광차폐유무와 방사성 동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구

이용수 0

영문명
Study on the Difference in Intake Rate by Kidney in Accordance with whether the Bladder is Shielded and Injection method in ⁹⁹ᵐTc-DMSA Renal Scan for Infants
발행기관
대한핵의학기술학회
저자명
박정균(Jeong Kyun Park) 차재훈(Jae Hoon Cha) 김광현(Kwang Hyun Kim) 안종기(Jong Ki An) 홍다영(Da Young Hong) 성효진(Hyo Jin Seong)
간행물 정보
『핵의학기술』Vol.20 No.2, 27~31쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2016.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose ⁹⁹ᵐTc-DMSA renal scan is a test for the comparison of the function by imaging the parenchyma of the kidneys by the cortex of a kidney and by computing the intake ratio of radiation by the left and right kidney. Since the distance between the kidneys and the bladder is not far given the bodily structure of an infant, the bladder is included in the examination domain. Research was carried out with the presumption that counts of bladder would impart an influence on the kidneys at the time of this renal scan. In consideration of the special feature that only a trace amount of a RI is injected in a pediatric examination, research on the method of injection was also carried out concurrently. Materials and Methods With 34 infants aged between 1 month to 12 months for whom a ⁹⁹ᵐTc-DMSA renal scan was implemented on the subjects, a Post IMAGE was acquired in accordance with the test time after having injected the same quantity of DMSA of 0.5mCi. Then, after having acquired an additional image by shielding the bladder by using a circular lead plate for comparison purposes, a comparison was made by illustrating the percentile of (Lt. Kidney counts + Rt. Kidney counts)/ Total counts, by drawing the same sized ROI (length of 55.2mm X width of 70.0mm). In addition, in the format of a 3-way stopcock, a Heparin cap and direct injection into the patient were performed in accordance with RI injection methods. The differences in the count changes in accordance with each of the methods were compared by injecting an additional 2cc of saline into the 3-way stopcock and Heparin cap. Results The image prior to shielding of the bladder displayed a kidney intake rate with a deviation of 70.9±3.18% while the image after the shielding of the bladder displayed a kidney intake rate with a deviation of 79.4±5.19%, thereby showing approximately 6.5~8.5% of difference. In terms of the injection method, the method that used the 3-way form, a deviation of 68.9±2.80% prior to the shielding and a deviation of 78.1±5.14% after the shielding were displayed. In the method of using a Heparin cap, a deviation of 71.3±5.14% prior to the shielding and a deviation of 79.8±3.26% after the shielding were displayed. Lastly, in the method of direct injection into the patient, a deviation of 75.1±4.30% prior to the shielding and a deviation of 82.1±2.35% after the shielding were displayed, thereby illustrating differences in the kidney intake rates in the order of direct injection, a Heparin cap and the 3-way methods. Conclusion Since a substantially minute quantity of radiopharmaceuticals is injected for infants in comparison to adults, the cases of having shielded the bladder by removing radiation of the bladder displayed kidney intake rates that are improved from those of the cases of not having shielded the bladder. Although there are difficulties in securing blood vessels, it is deemed that the method of direct injection would be more helpful in acquisition of better images since it displays improved kidney intake rate in comparison to other methods.

목차

서론
연구대상 및 방법
결과
결론 및 고찰
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

박정균(Jeong Kyun Park),차재훈(Jae Hoon Cha),김광현(Kwang Hyun Kim),안종기(Jong Ki An),홍다영(Da Young Hong),성효진(Hyo Jin Seong). (2016).소아 ⁹⁹ᵐTc-DMSA renal scan에서 방광차폐유무와 방사성 동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구. 핵의학기술, 20 (2), 27-31

MLA

박정균(Jeong Kyun Park),차재훈(Jae Hoon Cha),김광현(Kwang Hyun Kim),안종기(Jong Ki An),홍다영(Da Young Hong),성효진(Hyo Jin Seong). "소아 ⁹⁹ᵐTc-DMSA renal scan에서 방광차폐유무와 방사성 동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구." 핵의학기술, 20.2(2016): 27-31

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제