PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰

이용수 0

영문명
Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT
발행기관
대한핵의학기술학회
저자명
김준(June Kim) 김재일(Jae-II Kim) 이홍재(Hong-Jae Lee) 김진의(Jin-Eui Kim)
간행물 정보
『핵의학기술』Vol.20 No.2, 21~26쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2016.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted ¹⁸F- FDG 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count –to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient(66±15age) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is 8±0.5%, correction factor of organs with CT number similar to soft tissue is 6±2% and correction factor of organs with low CT number(-100>) is 3±1%. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn`t happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -tonon attenuation correction image count ratio is one of the methods to reduce metal artifact affect

목차

서론
대상 및 방법
결과
결론
요약
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김준(June Kim),김재일(Jae-II Kim),이홍재(Hong-Jae Lee),김진의(Jin-Eui Kim). (2016).PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰. 핵의학기술, 20 (2), 21-26

MLA

김준(June Kim),김재일(Jae-II Kim),이홍재(Hong-Jae Lee),김진의(Jin-Eui Kim). "PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰." 핵의학기술, 20.2(2016): 21-26

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제