학술논문
PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰
이용수 0
- 영문명
- Metal artifact SUV estimation by using attenuation correction image and non attenuation correction image in PET-CT
- 발행기관
- 대한핵의학기술학회
- 저자명
- 김준(June Kim) 김재일(Jae-II Kim) 이홍재(Hong-Jae Lee) 김진의(Jin-Eui Kim)
- 간행물 정보
- 『핵의학기술』Vol.20 No.2, 21~26쪽, 전체 6쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2016.10.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose Because of many advantages, PET-CT Scanners generally use CT Data for attenuation correction. By using CT based attenuation correction, we can get anatomical information, reduce scan time and make more accurate correction of attenuation. However in case metal artifact occurred during CT scan, CT-based attenuation correction can induce artifacts and quantitative errors that can affect the PET images. Therefore this study infers true SUV of metal artifact region from attenuation corrected image count -to- non attenuation corrected image count ratio. Materials and Methods Micro phantom inserted ¹⁸F- FDG 4mCi was used for phantom test and Biograph mCT S(40) is used for medical test equipment. We generated metal artifact in micro phantom by using metal. Then we acquired both metal artifact region of correction factor and non metal artifact region of correction factor by using attenuation correction image count –to- non attenuation correction image count ratio. In case of clinical image, we reconstructed both attenuation corrected images and non attenuation corrected images of 10 normal patient(66±15age) who examined PET-CT scan in SNUH. After that, we standardize several organs of correction factor by using attenuation corrected image count -to- non attenuation corrected count ratio. Then we figured out metal artifact region of correction factor by using metal artifact region of attenuation corrected image count -to- non attenuation corrected count ratio And we compared standard organs correction factor with metal artifact region correction factor. Results according to phantom test results, metal artifact induce overestimation of correction factor so metal artifact region of correction factors are 12% bigger than the non metal artifact region of correction factors. in case of clinical test, correction factor of organs with high CT number(>1000) is 8±0.5%, correction factor of organs with CT number similar to soft tissue is 6±2% and correction factor of organs with low CT number(-100>) is 3±1%. Also metal artifact correction factors are 20% bigger than soft tissue correction factors which didn`t happened metal artifact. Conclusion metal artifact lead to overestimation of attenuation coefficient. because of that, SUV of metal artifact region is overestimated. Thus for more accurate quantitative evaluation, using attenuation correction image count -tonon attenuation correction image count ratio is one of the methods to reduce metal artifact affect
목차
서론
대상 및 방법
결과
결론
요약
References
해당간행물 수록 논문
- Tongue Cancer 환자에서 PET/CT 검사 시 Open Mouth 촬영법의 유용성 평가
- 성조숙증 여아들의 임상적 특징 및 진단별 성선자극호르몬 분비호르몬 GnRH (Gonado Tropin Releasing Hormone) 검사결과의 비교분석평가
- PET-CT에서 감쇠보정 영상과 비감쇠보정 영상을 통한 Metal Artifact 보정에 대한 고찰
- 감시림프절 검사 시 입자크기에 따른 대체 방사성의약품의 유용성평가
- 범용 신틸레이터 감마카메라와 심근전용 반도체 감마카메라의 성능 비교 연구
- TSH, FT4 검사의 Two-point Calibration Curve 적용의 유용성 평가
- ¹⁸F-Florbetaben 주사 시 Activity 손실과 통증 감소를 위한 방법
- Excel의 추세선을 이용한 표준곡선 검증
- 비뇨기암 환자에서 ¹¹C-Acetate 양전자 방출 컴퓨터 단층 검사 (PET-CT)의 임상 적용
- 소아 ⁹⁹ᵐTc-DMSA renal scan에서 방광차폐유무와 방사성 동위원소 주입방법에 따른 콩팥섭취율 차이에 관한 연구
- 핵의학 검사 시행하는 환자에 의한 병원 종사자 피폭선량 평가
- PET/CT 검사에서 Gastrointestinal Cancer 환자의 Liver 추가촬영에 대한 유용성 평가
- 용액에 따른 자동분주기의 분주능력 평가와 분주력 향상 실험
- PET 검사 시 Reconstructed data와 Re-sliced data의 표준섭취계수와 Metabolic Tumor Volume의 비교 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- Attention UNet 모델을 활용한 유방 초음파 영상 분할: IoU 기반 학습 및 AUC, MSE 평가
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 삼중수소 측정 신뢰성 검증을 위한 국제숙련도시험 결과 평가
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!