학술논문
동적신장검사에서 신장깊이에 따른 사구체여과율 비교
이용수 0
- 영문명
- The Comparison of Glomerular Filteration Rate by Kidney Depth in Dynamic kidney Scan
- 발행기관
- 대한핵의학기술학회
- 저자명
- 황주원(Ju-Won Hwang) 임영현(Young-Hyen Lim) 윤종준(Jong-Jun Yun) 이화진(Hwa-Jin Lee) 이무석(Mu-Seok Lee) 정지욱(Ji-Uk Jung) 박세윤(Se-Yun Park)
- 간행물 정보
- 『핵의학기술』Vol.18 No.2, 73~77쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2014.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose Find out about the significance of the GFR values calculated by the kidney depth is measured by comparing the values obtained for kidney depth was measured GFR in the CT image kidney depth and is calculated by Tonnesen law in ⁹⁹ᵐTc-DTPA dynamic kidney scan with each applies. Materials and Methods Among patients with normal value (75~120 mL/min) computed GFR conducted of dynamic renal scan to visit from February 2013 to February 2014 and donor GFR values in patients with normal value. The mean age was 46.9 years with 14 men 13 females. We used abdomen CT image which checked before conducting dynamic Kidney scan for measuring the depth of kidney. We only used CT image that contains renal hilum and measured outermost front of the kidney from the skin surface (a) and the final surface (b) caculated the average depth of [(a + b) / 2] respectively. Using the same ROI in order to limit the change in GFR values by the other additional element was set before and after the depth value was excluded from the GFR falls kidney disease. Results Using Tonnesen law the average value was caculated 5.94 cm from the right kidney 5.90 cm from the left kidney. It was 6.83 cm, 8.71 cm in the left kidney and the right kidney average value of the depth measured on the basis of the CT image. The respective increase in left kidney 0.93 cm and right kidney 2.77 cm calculated on the basis of CT image actually measured values. GFR was calculated as the average depth of the subject calculated by the method Tonnesen 83.3±9.79 mL/min. 98.6±14.07 mL/min GFR was applied to calculate the average depth of the subjects using the CT image, is the difference appears 15.26 mL/min was increased after seting up depth value, P value was less than 0.01 which is significant. Conclusion The difference between GFR before-after setting up depth value cause that the different of depth value. Is a measured depth of the extension value of the calculated estimates Whereas Tonnesen kidney depth method is to use in calculating the value of GFR in a typical dynamic elongation test depth derived using the CT image depth. Is thought to be able to calculate more accurately the GFR value by the distance to the center of kidney more accurately measured in the skin thereby.
목차
서론
실험장비 및 재료
실험대상 및 방법
결과
고찰 및 결론
요약
REFERENCE
키워드
해당간행물 수록 논문
- SPECT/CT에서 인공고관절에 대한 감쇠보정지도 (Attenuation Map)의 매개변수 변화에 따른 금속 인공물 (Metal Artifact)의 영향 평가
- 심근관류 SPECT에서 움직임 보정 방법들의 비교
- PET-CT 검사에서 ¹⁸F-FDG 투여량 감소에 대한 고찰
- PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가
- 신 공여자 에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰
- ¹⁸F-FDG와 ⁹⁹ᵐTcO₄⁻를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구
- 동적신장검사에서 신장깊이에 따른 사구체여과율 비교
- 간담도스캔의 영상수집방법에 따른 담즙배출율의 비교분석
- SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰
- GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션
- ⁹⁹ᵐTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성
- 생활 스트레스에 대한 심박변이와 혈청 코티졸과의 관계
- 자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
