학술논문
자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰
이용수 0
- 영문명
- The study of Breast Specific Gamma Imaging Protocol using Self-development Phantom
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이해정(Hae-Jung Lee) 이주영(Juyoung Lee) 임근교(Kuen-Kyo Lim) 박훈희(Hoon-Hee Park)
- 간행물 정보
- 『핵의학기술』Vol.18 No.2, 39~47쪽, 전체 9쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2014.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

국문 초록
영문 초록
Purpose As breast cancer patients continue to increase every year, cases of BSGI are on the rise with a heavier reliance on it. However, BSGI protocol in hospitals was not studied enough despite it was covered by hospital’s condition and recommendation of manufacturers. The objective of the study was an examination of methods to be applicable to BSGI protocols, putting the self-development phantom to use in quality assessment of the images. Materials and Methods Dilon 6800 (Dilon Technologies Inc, Newport News, USA) was used in the study and five different sizes of sphere were distinctively produced in the phantom. The study used ⁹⁹ᵐTcO₄. The cases were classified in to three categories that background radioactivity to region of interest as ratio of 2: 4: 8, They were acquired images for 5, 7, 10mins. The acquired image was set region of interest according to the size of sphere, and We analyzed quantitative and qualitative analysis. The acquired data statistically analyzed with SPSS ver.18.0. Results As the result of quantitative and qualitative analysis, count rate of each sphere in accordance with difference of injection dose showed that higher count rate as injection dose and sphere size increased (P<0.005). Count rate of each sphere in accordance with difference of acquisition time showed that higher count rate as acquisition time and sphere size increased (P<0.005). Contrast noise ratio of each sphere in accordance with difference of injection dose showed that higher contrast noise ratio as injection dose increased. Particularly, Contrast noise ratio of eight times ratio images was the highest among. Contrast noise ratio of each sphere in accordance with difference of acquisition time showed that higher contrast noise ratio as acquisition time increased. And, Contrast noise ratio of seven minute image was the highest among (P<0.005). Conclusion There was significant change of Contrast noise ratio through quantitative and qualitative analysis. Moreover, We found usefulness of phantom. If Institutions identified image through the phantom study and they made BSGI protocol, We expected to help the improvement of diagnostic value of the images.
목차
서론
대상 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- SPECT/CT에서 인공고관절에 대한 감쇠보정지도 (Attenuation Map)의 매개변수 변화에 따른 금속 인공물 (Metal Artifact)의 영향 평가
- 심근관류 SPECT에서 움직임 보정 방법들의 비교
- PET-CT 검사에서 ¹⁸F-FDG 투여량 감소에 대한 고찰
- PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가
- 신 공여자 에서 신장 깊이 측정에 따른 사구체여과율의 비교에 관한 고찰
- ¹⁸F-FDG와 ⁹⁹ᵐTcO₄⁻를 이용한 당일 검사 시 상호 영향에 대한 Phantom 연구
- 동적신장검사에서 신장깊이에 따른 사구체여과율 비교
- 간담도스캔의 영상수집방법에 따른 담즙배출율의 비교분석
- SPECT/CT에서 자동노출제어(AEC)를 이용함으로써 얻어지는 영상의 질 평가와 피폭선량 감소에 관한 고찰
- GEANT4를 이용한 치료용 I-131 캡슐의 안정성 시뮬레이션
- ⁹⁹ᵐTc-DTPA를 이용한 사구체여과율 검사에서 이소성 신장과 소아 환자의 신장 깊이 측정방법의 적절성
- 생활 스트레스에 대한 심박변이와 혈청 코티졸과의 관계
- 자체 제작된 팬텀을 적용한 Breast Specific Gamma Imaging 검사 프로토콜에 대한 고찰
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 방사선학과 학생 실습환경에 관한 연구: 실습실 내 미세먼지, 휘발성유기화합물 위해도를 중심으로
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- 추출 크로마토그래피를 이용한 55Fe와 59/63Ni의 화학분리 중 목적원소 및 방해원소 거동 특성 연구
- 진단참고 준위를 적용한 선량 변화에 따른 영상 품질의 변화 평가
- 호주 방사선 의료 전문가 면허제도 및 교육과정 고찰: 진단방사선사를 중심으로
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!
