PET-CT 검사에서 ¹⁸F-FDG 투여량 감소에 대한 고찰

이용수 0

영문명
Reduction of Injection Dose in ¹⁸F-FDG Fusion PET
발행기관
대한핵의학기술학회
저자명
김종필(Jong-Pil Kim) 김재일(Jae-Il Kim) 이홍재(Hong-Jae Lee) 김진의(Jin-Eui Kim)
간행물 정보
『핵의학기술』Vol.18 No.2, 17~21쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2014.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose With the recent rise of social issue regarding radiation exposure, attention to medical radiation use has been placed under a great spotlight. During PET-CT examination, generally about 40% more of ¹⁸F-FDG is used than EANM recommendation. While maintaining the diagnostic test result, we hope to find optimal injection dose to minimize the ¹⁸F-FDG in patients by utilizing the latest PET-CT scanner which is equiped with the newest technology. Materials and Methods During this experiment, the Biograph Truepoint 40 (siemens, USA) installed in 2007 and mCT 64 (siemens, USA) installed in 2011 were used and evaluated NECR (noise-equivalent counting rate) by using a scatter phantom. For the image quality evaluation of each scanner, we injected 3.7, 4.44 and 5.18 MBq/kg of ¹⁸F-FDG in NEMA IEC Body Phantom and also evaluated SNR between two scanners by using the data acquired at 60, 70, 80, 90, 100, 110 and 120 sec per bed. For the clinical evaluation, actual data of patients who were injected ¹⁸F-FDG 3.7, 4.44, 5.18 MBq/kg were used to compare SNR and draw a final result. Results As a result, mCT 64 peak NECR value was 1.65e+005, which is 10% higher than Turepoint 40. SNR values using the IEC body phantom was 17.9%, 17.4% and 17.1% higher in ¹⁸F-FDG 3.7 MBq/kg, 4.44 MBq/kg and 5.18 MBq/kg. In clinical patients, SNR values of the image mCT 64 was 16.5, which is 25% higher than Turepoint 40 scanner. Conclusion To draw a conclusion from the test result of this experiment, the same quality of SNR could be attained even with 10% reduced injection dose, if when the duration is extended by 10 sec/bed. This optimal result was possible due to enhanced equipment. The NECR (one of the equipment’s performance assessment criteria for the scanner) increased by 10% and the SNR (one of the image quality assessment criteria) also increased by 17.5%. Therefore, we can expect to reduce the injection dose without deterioration of image quality. In consequence, it will also help to decrease the patient’s anxiety of the radiation exposure.

목차

서론
실험 재료 및 방법
결과
결론 및 고찰
요약
References

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김종필(Jong-Pil Kim),김재일(Jae-Il Kim),이홍재(Hong-Jae Lee),김진의(Jin-Eui Kim). (2014).PET-CT 검사에서 ¹⁸F-FDG 투여량 감소에 대한 고찰. 핵의학기술, 18 (2), 17-21

MLA

김종필(Jong-Pil Kim),김재일(Jae-Il Kim),이홍재(Hong-Jae Lee),김진의(Jin-Eui Kim). "PET-CT 검사에서 ¹⁸F-FDG 투여량 감소에 대한 고찰." 핵의학기술, 18.2(2014): 17-21

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제