시약 변경 시 모집단 분포 추이에 따른 결과 분석
이용수 2
- 영문명
- Result Analysis according to Population Distribution Trends when Reagents are Changed
- 발행기관
- 대한핵의학기술학회
- 저자명
- 박혜미(Hye-Mi Park) 임수연(Soo-Yeon Lim) 유선희(Sun-Hee Yoo) 이선호(Sun-Ho Lee)
- 간행물 정보
- 『핵의학기술』Vol.27 No.1, 59~66쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2023.05.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: In this study, the monthly population distribution was calculated for statistical verification of 10 tests (CA19-9, CA15-3, testosterone, PTH, calcitonin, AFP, CEA, CA72-4, PSA, estradiol) with changed reagents, and the trend of change By comparing and analyzing the results, we want to verify the accuracy of the results and improve the reliability of the test. Materials and Methods: From June 2021 to February 2023, for the 10 items in which the reagent was changed, the monthly percentage and standard deviation index before and after the reagent change were compared, respectively. At this time, the reference value was arbitrarily set for the comparison group in consideration of the reference value of the test item, and the groups were subdivided and compared, and the standard deviation index allowed range was -2.0 or more and 2.0 or less. Results: For CA19-9, CA15-3, AFP, CEA, and calcitonin 5 test items, the change in monthly ratio in all test sections before and after the reagent change was kept constant. On the other hand, for CA72-4, PSA, testosterone, PTH, and estradiol items, the standard deviation index exceeded the acceptable standard after changing the reagent. CA72-4 test items showed an increasing trend in standard deviation index in the test section exceeding the reference value. In the case of the PSA test item, the maintenance ratio of 0.04 ng/mL was significantly decreased after changing the reagent. The testosterone test item had a standard deviation index of -2.5 in the test section exceeding 10.1 ng/mL after changing the reagent, and the standard deviation index of the PTH test item was out of the acceptable range in all test sections. It was confirmed that the estradiol test item showed an overall increase in the result value. Conclusion: Through this study, the continuity and accuracy of the test results could be verified. It is considered that the stability of the test can be secured by analyzing the factors affecting the test result and solving the cause for the test item whose standard deviation index is out of the acceptable standard.
목차
서론
실험 재료 및 방법
결과
결론
고찰
REFERENCE
해당간행물 수록 논문
- 개인선량계 분실 사례 및 분실 방지 방안 조사
- 시약 변경 시 모집단 분포 추이에 따른 결과 분석
- Femoral Metastasis in Bone Mineral Densitometry
- Femoral Cystic Lesion in Bone Mineral Densitometry
- Splenic Absorption of Radiopharmaceutical in Systemic Bone Scans Performed after Liver Transplantation
- 의료기기의 발전을 위한 탄소소재의 활용
- 채혈 시간에 따른 부신피질 자극 호르몬 검사의 참고치 설정에 관한 고찰
- 감마카메라의 중장기 외인성 균일도 분석
- 대뇌 신경 교종 18F-FDG PET/CT 검사에서 포도당 부하 기법에 대한 고찰
- PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가
- DXA 골밀도 검사에서 방사선사가 인식하고 있어야 할 Pitfall
- 면역방사계수측정법의 민감도 향상을 위한 변법의 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 민간의료보험 해약 의향 영향 요인: 한국 의료 패널 2019년 2기 자료를 이용하여
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- 임상에서 사용되는 온장고 온도설정 및 한계점에 대한 고찰
의약학 > 방사선과학분야 NEW
- Attention UNet 모델을 활용한 유방 초음파 영상 분할: IoU 기반 학습 및 AUC, MSE 평가
- RI 등 사용 허가 대학의 정기 검사 수검 사례: 방사선학과를 대상으로
- 삼중수소 측정 신뢰성 검증을 위한 국제숙련도시험 결과 평가
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!