PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가

이용수 0

영문명
Evaluation of Image for Phantom according to Normalization, Well Counter Correction in PET-CT
발행기관
대한핵의학기술학회
저자명
이충운(Choong-Woon Lee) 유연욱(Yeon-Wook You) 문종운(Jong-Woon Mun) 김윤철(Yun-Cheol Kim)
간행물 정보
『핵의학기술』Vol.27 No.1, 37~46쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2023.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: PET-CT imaging require an appropriate quality assurance system to achieve high efficiency and reliability. Quality control is essential for improving the quality of care and patient safety. Currently, there are performance evaluation methods of UN2-1994 and UN2-2001 proposed by NEMA and IEC for PET-CT image evaluation. In this study, we compare phantom images with the same experiments before and after PET-CT 3D normalization and well counter correction and evaluate the usefulness of quality control. Materials and methods: Discovery 690 (General Electric Healthcare, USA) PET-CT equiptment was used to perform 3D normalization and well counter correction as recommended by GE Healthcare. Based on the recovery coefficients for the six spheres of the NEMA IEC Body Phantom recommended by the EARL. 20kBq/㎖ of 18F was injected into the sphere of the phantom and 2kBq/㎖ of 18F was injected into the body of phantom. PET-CT scan was performed with a radioacitivity ratio of 10:1. Images were reconstructed by appliying TOF+PSF+TOF, OSEM+PSF, OSEM and Gaussian filter 4.0, 4.5, 5.0, 5.5, 6.0, 6,5 ㎜ with matrix size 128×128, slice thickness 3.75 ㎜, iteration 2, subset 16 conditions. The PET image was attenuation corrected using the CT images and analyzed using software program AW 4.7 (General Electric Healthcare, USA). The ROI was set to fit 6 spheres in the CT image, RC (Recovery Coefficient) was measured after fusion of PET and CT. Statistical analysis was performed wilcoxon signed rank test using R. Results: Overall, after the quality control items were performed, the recovery coefficient of the phantom image increased and measured. Recovery coefficient according to the image reconstruction increased in the order TOF+PSF, TOF, OSEM+PSF, before and after quality control, RCmax increased by OSEM 0.13, OSEM+PSF 0.16, TOF 0.16, TOF+PSF 0.15 and RCmean increased by OSEM 0.09, OSEM+PSF 0.09, TOF 0.106, TOF+PSF 0.10. Both groups showed a statistically significant difference in wilcoxon signed rank test results (P value<0.001). Conclusion: PET-CT system require quality assurance to achieve high efficiency and reliability. Standardized intervals and procedures should be followed for quality control. We hope that this study will be a good opportunity to think about the importance of quality control in PET-CT

목차

서론
대상 및 방법
결과
고찰
결론
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이충운(Choong-Woon Lee),유연욱(Yeon-Wook You),문종운(Jong-Woon Mun),김윤철(Yun-Cheol Kim). (2023).PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가. 핵의학기술, 27 (1), 37-46

MLA

이충운(Choong-Woon Lee),유연욱(Yeon-Wook You),문종운(Jong-Woon Mun),김윤철(Yun-Cheol Kim). "PET-CT Normalization, Well Counter Correction에 따른 팬텀을 이용한 영상 평가." 핵의학기술, 27.1(2023): 37-46

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제