면역방사계수측정법의 민감도 향상을 위한 변법의 평가

이용수 0

영문명
Evaluation of Variation Method to Improve the Sensitivity of Immunoradiometric Assay
발행기관
대한핵의학기술학회
저자명
권원현(Won-Hyun Kwon) 강미지(Mi-Ji Kang) 김나경 박지솔(Ji-Sol Park) 김정인(Jung-In Kim) 이경재(Kyung-Jae Lee)
간행물 정보
『핵의학기술』Vol.27 No.1, 29~36쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2023.05.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: The concentration of PSA (Prostate Specific Antigen) after radical prostatectomy in prostate cancer patients is a predictor of biochemical recurrence, and the AUA (American Urological Association) is defined as biochemical recurrence when the concentration of PSA is measured at 0.2 ng/mL or more, and when the concentration is measured at 0.2 ng/mL or more at the retest. This standard is also applied our hospital. In this laboratory, the PSA reagent using IRMA (Immunoradiometric Assay) is used, and the sensitivity at a very low value was not as good as the reagent used in the department of laboratory medicine. This study aims to increase the reliability of the results by improving the precision and sensitivity of very low values. Materials and Methods: As a reagent for the study, PSA reagent using IRMA was used. As a method to improve the precision and sensitivity of very low values, a variation method on the serum volume (25 uL, 50 uL, 100 uL, 200 uL) was studied, and variation usefulness evaluation was conducted. The evaluation items were compared the results of precision, analytical sensitivity, recovery rate, dilution test, high-dose hook effect test, parallel test and very low concentration values (n = 20). Results: The validation results were displayed in the order of 25 uL, 50 uL, 100 uL, 200 uL. As the serum volume increased, it was confirmed that CV (Coefficient of Variation)(%) improved. Analytical sensitivity (ng/mL) was 0.038, 0.041, 0.017, 0.015 and recovery rate (%) was 101±3, 101±3, 99±2, 97±4. very low concentration values (ng/mL) between each volume (n=20) were 0.135±0.068, 0.076±0.050, 0.048±0.034, 0.046±0.034. and high dose hook effect appeared as the serum volume increased. Conclusion: Through the variation usefulness evaluation, it was confirmed that as the serum volume increased, the precision and sensitivity improved at very low concentration values. However, it is necessary to pay special attention to the occurrence of high-dose hook effect as the serum volume increases. In the case of tests that requires very low concentration values, it is thought that the reliability of the result will be increased if the variation method is properly used after the variation usefulness evaluation.

목차

서론
실험재료 및 방법
고찰
결론
REFERENCE

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

권원현(Won-Hyun Kwon),강미지(Mi-Ji Kang),김나경,박지솔(Ji-Sol Park),김정인(Jung-In Kim),이경재(Kyung-Jae Lee). (2023).면역방사계수측정법의 민감도 향상을 위한 변법의 평가. 핵의학기술, 27 (1), 29-36

MLA

권원현(Won-Hyun Kwon),강미지(Mi-Ji Kang),김나경,박지솔(Ji-Sol Park),김정인(Jung-In Kim),이경재(Kyung-Jae Lee). "면역방사계수측정법의 민감도 향상을 위한 변법의 평가." 핵의학기술, 27.1(2023): 29-36

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제