PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가

이용수 0

영문명
The Effectiveness Evaluation of Reconstruction Method Using DFOV Position Changes for Reduction of Artifact Around Hotspot in PET/CT Images
발행기관
대한핵의학기술학회
저자명
한동찬(Dong Chan Han) 홍건철(Gun Chul Hong) 최춘기(Choon ki Choi) 이혁(Hyeok Lee) 최성욱(Seong Wook Choi)
간행물 정보
『핵의학기술』Vol.17 No.2, 90~94쪽, 전체 5쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2013.11.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: In the PET/CT images, various artifacts cause degradation of the quantitative assessment. Most hotspot generated by radiopharmaceutical injection errors cause an artifact and degrade the quality of the images as well as the accuracy of the quantitative evaluation. The purpose of this study is to assess effectiveness of the elimination of the hotspot at the injection sites using shifting the center of DFOV (Display Field of View, DFOV) method and evaluate the quantitative evaluation of result. Materials and Methods: GE Discovery STE 16 (GE Healthcare, Milwaukee, USA) and 1994 NEMA phantom were used for imaging acquisition. Phantom was filled with 0.005 MBq/mL of ¹⁸F-FDG. A hotspot was artificially placed on the outside of the phantom. The ratio of hotspot area activity to background area activity was regulated as 200:1. After image acquisition with routine protocol, all of the images were reconstructed using the shifting the center of DFOV method that wasn't overlapped with hotspot. Those images obtained before and after applying the shifting reconstruction method were compared. ROIs (Region Of Interests) were set in the hotspot areas, meanSUVs and standard deviations were calculated. Percentage differences were calculated with those meanSUVs and standard deviations. The evaluation on the effects of the shifting reconstruction method was done by comparison of the meanSUVs and the standard deviations, which were calculated for background areas unaffected by hotspot. Results: In the areas of unaffected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were 0.67±0.06 g/mL and 0.65±0.06 g/mL, respectively. In the artifact areas affected by hotspot, meanSUVs before and after applying the shifting of center of DFOV method were 0.32±0.08 g/mL and 0.56±0.12 g/mL, respectively. The percentage differences of the area adjacent to the hotspot and the area distant from the hotspot were 65.3% and 97.4%, respectively. Conclusion: In the PET/CT images, meanSUV was improved by 32.1% when the effect of artifact was removed with application of the shifting the center of DFOV methode. In other areas unaffected by artifacts, meanSUVs were not significantly different after applying DFOV center shift method. As shown in the result, adverse effects of hotspot made by swelling in the injection site can be reduced by applying DFOV center shift method. Therefore, DFOV center shift method can be applied for the more precise quantitative evaluation, and contribute to the increase of the diagnostic value of the images.

목차

서론
실험재료 및 방법
결과
결론
고찰
요약
REFERENCES

키워드

*,

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

한동찬(Dong Chan Han),홍건철(Gun Chul Hong),최춘기(Choon ki Choi),이혁(Hyeok Lee),최성욱(Seong Wook Choi). (2013).PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가. 핵의학기술, 17 (2), 90-94

MLA

한동찬(Dong Chan Han),홍건철(Gun Chul Hong),최춘기(Choon ki Choi),이혁(Hyeok Lee),최성욱(Seong Wook Choi). "PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가." 핵의학기술, 17.2(2013): 90-94

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제