학술논문
(n,γ)⁹⁹Mo를 이용한 ⁹⁹Mo-99mTc발생기의 유용성 평가
이용수 0
- 영문명
- The Evaluation of Usefulness of ⁹⁹Mo-99mTc Generator Using(n,γ)⁹⁹Mo Developed by Korea Atomic Energy Research Institute
- 발행기관
- 대한핵의학기술학회
- 저자명
- 서한경(Han Kyung Seo) 김정호(Jeong Ho Kim) 심철민(Cheol Min Shim) 김병철(Byung Cheol Kim) 최도철(Do Cheol Choi) 권용주(Yong Ju Gwon) 박영순(Yung Sun Park) 김동윤(Dong Yun Kim)
- 간행물 정보
- 『핵의학기술』Vol.17 No.2, 48~52쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2013.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: The Molybdenum which is the raw material of ⁹⁹Mo-⁹⁹ᵐTc generator is produced from the nuclear reactor. However, output has dwindled as the two nuclear reactors supplying the bulk of radioactive material-one in Chalk River, Ontario and the other in Petten, the Netherlands-have been closed for repairs or maintenance. This resulted in the enhancement of its price. So ⁹⁹Mo-⁹⁹ᵐTc generator using(n,γ)⁹⁹Mo is developed by Korea Atomic Energy Research Institute (KAERI). Medicinal availability of this generator is evaluated in this study. Materials and Methods: The radioactivity of ⁹⁹ᵐTc eluted in generator 1, 2 and 3 unit developed by KAERI was measured. The quality control test of generator such as appearance test, pH test, LAL test, sterility test, chemical impurity (Al) test and radiochemical purity test were performed. Planar and SPECT/CT image sof SD rat (6 weeks, Female) at 2 hr after injection of ⁹⁹ᵐTc-HDP (hydroxymethylenediphosphonate) (TechneScan HDP, Malinckrodt Medical, Dutch) and ⁹⁹ᵐTc-DPD (diphosphono-1, 2-propanedicarboxylicacid) (TECEOS, CIS bio international, France) which were labeled with ⁹⁹ᵐTc eluted in KAERI and commercial generator (40.5 GBq, Malinckrodt Medical, Dutch) using SPECT/CT camera (Symbia, Siemense, Germany) were obtained respectively. Results: The mean radioactivity of ⁹⁹ᵐTc elution generator 1unit was 4.18 GBq (113 mCi), generator 2 unit was 4.73 GBq (128 mCi) and generator 3 unit was 3.33 GBq (90 mCi). All quality control tests were within normal limit except pyrogentest. Pyrogen test was positive. Planar and SPECT/CT images of rat injected ⁹⁹ᵐTc-HDP which was labeled with ⁹⁹ᵐTc eluted in commercial generator show increased uptake in bone, stomach and bowl. Planar images show increased uptake in liver and bone in case of ⁹⁹ᵐTc-DPD. However, images of rat injected ⁹⁹ᵐTc-HDP and ⁹⁹ᵐTc-DPD which were labelled ⁹⁹ᵐTc eluted in KAERI generator show increased uptake in bone, liver and spleen. Conclusion: If shortcoming is removed such as pyrogen and liver appearance, domestic role as an alternative generator is thought to be able to fill and to secure the national medical service by supplying ⁹⁹ᵐTc when the supply of ⁹⁹ᵐTc be comes short.
목차
서론
대상 및 방법
결과
요약
REFERENCES
해당간행물 수록 논문
- 인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화
- 식도암 환자의 GET 영상 평가
- PET/CT 검사에서 2024-04-08¹⁸F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰
- (n,γ)⁹⁹Mo를 이용한 ⁹⁹Mo-99mTc발생기의 유용성 평가
- PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가
- A형 간염의 자연항체와 예방접종을 통한 항체 생성률의 역가 비교분석
- UBC 검사의 이상결과에 대한 연구
- 동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교
- 상ㆍ하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰
- PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계
- 융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발
- 방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰
- SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가
- PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰
- Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구
- SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가
- PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)