방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰
이용수 0
- 영문명
- A Study on the Usefulness of Auto Dispenser and Optimized Dispensing Method
- 발행기관
- 대한핵의학기술학회
- 저자명
- 이정은(JeoungEun Lee) 김호성(Hosung Kim) 류재광(Jaekwang Ryu) 정우영(Wooyoung Jung)
- 간행물 정보
- 『핵의학기술』Vol.17 No.2, 59~66쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2013.11.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose: Recently, there is an increase of the number of hospitals using auto dispenser to reduce occupational radiation exposure when drawing up of the ¹⁸F-FDG dose (5.18 MBq/kg) in a syringe from the dramatic high activity of ¹⁸F-FDG multidose vial. The aim of this study is to confirm that using auto dispenser actually reduces the radiation exposure for technologists. Also we analyzed the reproducibility of auto dispenser to find optimized dispensing method for the device. Materials and Methods: We conducted three experiments. Comparison of radiation exposure on chest and hands: The chest and hands exposure dose received by technologists during the injection were measured by electronic personal dosimeter (EPD) and ring TLD respectively. Reproducibility of dispensed volume: We draw up the normal saline into 5 and 2 mL syringe using auto dispenser by changing the volume from 1 to 15 mm for 5 times in the same setting of the volume. The weight of 5 normal saline dispensed from the device at same volume was measured using micro balance and calculated standard deviation and coefficient of variation. Reproducibility of dispensed radioactivity: We dispensed 362.6 MBq±10%of ¹⁸F-FDG in 5 and 2 mL syringes from the multidose vial of different specific activity. In the same setting of volume, we repeated dispensing for 4 times and compared standard deviation and coefficient of variation of radioactivity between 5 syringes. Results: There was significant difference in the average of chest exposure dose according to the dispensing methods (P<0.05). Also, when dispensing ¹⁸F-FDG in manual method, exposure dose was 11.5 times higher in right hand and 4.8 times higher in left hand than in auto method. In the result of reproducibility of dispensed volume, standard deviation and coefficient of variation shows decline as the dispensing volume increases. As a result of reproducibility of dispensed radioactivity, standard deviation and coefficient of variation increases as the specific activity increases. Conclusion: We approved that the occupational radiation exposure dose of technologists were reduced when dispensing ¹⁸F-FDG using auto dose dispenser. Secondly, using small syringes helps to increase reproducibility of auto dose dispense. And also, if you lower the specific activity of ¹⁸F-FDG in multidose vial below 915-1,020 MBq/mL, you can use auto dispenser more effectively keeping the coefficient of variation lower than 10%.
목차
서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES
해당간행물 수록 논문
- 인체 각 부위의 PET/MRI와 PET/CT의 SUV 변화
- 식도암 환자의 GET 영상 평가
- PET/CT 검사에서 2024-04-08¹⁸F-FDG 투여 후 음악 청취 여부에 따른 SUV변화와 환자의 만족도에 관한 고찰
- (n,γ)⁹⁹Mo를 이용한 ⁹⁹Mo-99mTc발생기의 유용성 평가
- PET/CT 검사에서 열소 주변 인공물 감소를 위한 DFOV 위치 변화 재구성 방법의 유용성 평가
- A형 간염의 자연항체와 예방접종을 통한 항체 생성률의 역가 비교분석
- UBC 검사의 이상결과에 대한 연구
- 동적신장팬텀시스템 개발에 따른 장비별 사구체여과율의 비교
- 상ㆍ하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰
- PET/CT 검사 시 체중과 체표면적에 따른 SUV의 상관관계
- 융합영상(Fusion image)에서 움직임을 줄이기 위한 보정기구의 개발
- 방사성 의약품 자동 분주장치의 유용성 및 최적화된 분주방법에 관한 고찰
- SPECT/CT에서 서로 다른 에너지의 방사성동위원소 사용시 영상보정기법의 유용성 평가
- PET/CT 검사에서 환자체형에 따른 적정검사 프로토콜에 관한 고찰
- Hydronephrosis 환자의 Kidney MAG3 검사 시 Background ROI 설정에 따른 신장 상대 섭취율 변화에 관한 연구
- SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가
- PET/CT에서 Pitch와 Rotation Time의 변화를 이용한 능동적인 프로토콜 사용에 대한 연구
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!