본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가

이용수 0

영문명
The Usefulness Assessment of Attenuation Correction and Location Information in SPECT/CT
발행기관
대한핵의학기술학회
저자명
최종숙(Jong Sook Choi) 정우영(Woo Young Jung) 신상기(Sang Ki Shin) 조시만(Shee Man Cho)
간행물 정보
『핵의학기술』Vol.12 No.2, 214~221쪽, 전체 8쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2008.10.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose: We make a qualitative analysis of whether Fusion SPECT/CT can find lesion’s anatomical sites better than existing SPECT or not, and we want to show the usefulness of SPECT/CT through finding out effects of CT attenuation correction on SPECT images. Materials and Method: 1. The evaluation of fusion images: This study comprised patients who was tested 131I-MIBG, Bone, 111In- Octreotide, Meckel’s diverticulum, Parathyroid MIBI with Precedence 16 or Symbia T2 from 2008 Jan to Aug. We compared SPECT/CT image with non fusion image and make a qualitative analysis. 2. The evaluation of attenuation correction: We classified 38 patients who was tested 201Tl myocardial exam with Symbia T2 into 5 sections by using Cedars Sinai’ QPS program - Ant, Inf, Lat, Septum, Apex. And we showed each section’s perfusion states by percentage. We compared the each section’s perfusion-states differences between CT AC and Non AC by average±standard deviation. Results: 1. The evaluation of fusion images : In high energy 131I cases, it was hard to grasp exact anatomical lesions due to difference between regions and surrounding lesions’ uptake level. After combining with CT, we could grabs anatomical lesion more exactly. And in meckel’s diverticulum case or to find lesions around bowels or organs with 111In cases, it demonstrates its superiority. Bone SPECT/CT images help to distinguish between disk spaces certainly and give correct results. 2. The evaluation of attenuation correction: There is no significant difference statistically in Ant and Lat (p>0.05), but there is a meaningful difference in Inferior, Apex and Septum (p<0.05). AC perfusion at inferior wall in the 5 sections of myocardium: The perfusion difference between Non AC perfusion image (68.58±7.55) and CT corrected perfusion image (76.84±6.52) was the largest by 8.26±4.95 (p<0.01, t=10.29). Conclusion: Nuclear medicine physicians can identify not only molecular image which shows functional activity of lesions but also anatomical location information of lesions with more accuracy using the combination of SPECT and CT systems. Of course this combination helps nuclear medicine physician find out the abnormal parts. Moreover combined data sets help separate between normal group and abnormal group in complicated body part. So clinicians can carry out diagnosis and treatment planning at the same time with a single test image. In addition, when we examine a myocardium in thorax where attenuation can occur easily, we can trust perfusion more in a certain region in SPECT test because CT provides the capability for accurate attenuation correction. In these reasons, we think we can prove the justice after treatment fusion image.

목차

서론
실험재료 및 방법
결과
고찰
결론
요약
REFERENCES

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

최종숙(Jong Sook Choi),정우영(Woo Young Jung),신상기(Sang Ki Shin),조시만(Shee Man Cho). (2008).SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가. 핵의학기술, 12 (2), 214-221

MLA

최종숙(Jong Sook Choi),정우영(Woo Young Jung),신상기(Sang Ki Shin),조시만(Shee Man Cho). "SPECT/CT에서 감쇠 보정 및 위치 정보의 유용성 평가." 핵의학기술, 12.2(2008): 214-221

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제