학술논문
바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가
이용수 110
- 영문명
- Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs
- 발행기관
- 한국환경보건학회
- 저자명
- 차상원(Sangwon Cha) 오은하(Eunha Oh) 오세림(Selim Oh) 한상범(Sang Beom Han) 임호섭(Hosub Im)
- 간행물 정보
- 『1. 한국환경보건학회지』제47권 제1호, 64~77쪽, 전체 14쪽
- 주제분류
- 공학 > 환경공학
- 파일형태
- 발행일자
- 2021.02.28
4,480원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method.
Methods: 100 µL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS).
Results: The coefficient of determination (R²) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson’s correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson s correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method.
Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.
목차
I. 서 론
II. 재료 및 방법
III. 결과 및 고찰
IV. 결 론
해당간행물 수록 논문
- [레터] 새로운 50년을 위한 한국환경보건학회지의 비전과 실행 방향
- 유해화학물질 취급자의 개인보호구 착용에 대한 규정과 그 이행정도
- 일반인의 납 경구섭취량의 경시적 변화: 2008-2018년 국내자료를 중심으로
- [공지] 논문 투고 유형과 형식 변경 사전공고
- 수도권과 대구·경북지역의 일부 다중이용시설에서 흡연실 설치와 금연구역 정책 준수 수준 파악
- 바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가
- Cefotaxime을 이용한 PVA/PAA 하이드로 겔 필름의 항균 특성
- 어린이·청소년의 비스페놀 A 인체 노출에 영향을 미치는 요인: 제3기 국민환경보건 기초조사(2015-2017)
- [편집인 글] CMIT/MIT 가습기 살균제 판결문의 주요 논거에 대한 학술적 비평
- 어린이제품 내 프탈레이트류 및 대체제의 규제와 독성자료에 대한 연구
- 대구시 서구 산업단지 주변 지역의 악취오염도와 악취감시시스템 운영 평가
- 폐기물 소각시설에 의한 주민 건강 영향
참고문헌
관련논문
공학 > 환경공학분야 BEST
더보기공학 > 환경공학분야 NEW
- 도심환경교통(Urban Air Mobility, UAM) 도입에 따른 소음 문제에 대한 시론 -UAM 소음의 특성과 잠재적 건강영향: 연구 방향 및 관리를 위한 정책적 고려사항-
- 광주지역 공공수역의 미생물 군집 다양성 및 항생제 내성에 관한 연구
- 서울시 관악구 도림천 복개 정도에 따른 환경 악취 요인 분석
최근 이용한 논문