본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가

이용수 110

영문명
Development and Verification of a Simultaneous Analytical Method for Whole Blood Metals and Metalloids for Biomonitoring Programs
발행기관
한국환경보건학회
저자명
차상원(Sangwon Cha) 오은하(Eunha Oh) 오세림(Selim Oh) 한상범(Sang Beom Han) 임호섭(Hosub Im)
간행물 정보
『1. 한국환경보건학회지』제47권 제1호, 64~77쪽, 전체 14쪽
주제분류
공학 > 환경공학
파일형태
PDF
발행일자
2021.02.28
4,480

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Objective: Biological monitoring of trace elements in human blood samples has become an important indicator of the health environment. The purpose of this study was to detect and evaluate multiple metal items in blood samples based on ICP-MS, to perform comparative evaluation with the existing analysis method, and to develop and verify a new method. Methods: 100 µL of whole blood from 80 healthy subjects was used to analyze ten metals (Sb, tAs, Cd, Pb, Mn, Hg, Mo, Ni, Se, Tl) using ICP-MS. Verification of the analysis method included calculation of linearity, accuracy, precision and detection limits. In addition, a comparative test with the conventional graphite furnace atomic absorption spectroscopy (GF-AAS) method was performed. In the case of Pb, Cd, and Hg in whole blood, cross-analysis between Pb, Cd, and Hg analysis methods was performed to confirm the difference between the existing method and the new method (ICP-MS). Results: The coefficient of determination (R²) was 0.999 or higher in seven items and 0.995 or higher in three items. The Pb result showed that Pearson’s correlation coefficient was very high at 0.983, and the intraclass correlation coefficient was 0.966. The Cd result showed that Pearson s correlation coefficient was 0.917 between the existing method and the new analysis concentration value. Its intraclass correlation coefficient was 0.960, and there was no significant difference between the two groups. Hg had a low correlation at 0.687, and the intraclass correlation coefficient was 0.761, which was lower than that of Pb and Cd. The intra-day and inter-day accuracy of Pd and Cd were satisfactory, but Hg did not meet the criteria for both accuracy and precision when compared with the conventional analysis method. Conclusion: This study can be meaningful in that it proposes a more efficient and feasible analysis method by verifying a blood heavy metal concentration experiment using multiple simultaneous analyses. All samples were processed and analyzed using the new ICP-MS. It was confirmed that the agreement between the two methods was very high, with the agreement between the current and new methods being 0.769 to 0.998. This study proposes an efficient simultaneous methodology capable of analyzing multiple elements with small samples. In the future, studies of various applications and the reliability of ICP-MS analysis methods are required, and research on the verification of accurate, precise, and continuous analysis methods is required.

목차

I. 서 론
II. 재료 및 방법
III. 결과 및 고찰
IV. 결 론

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

차상원(Sangwon Cha),오은하(Eunha Oh),오세림(Selim Oh),한상범(Sang Beom Han),임호섭(Hosub Im). (2021).바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가. 1. 한국환경보건학회지, 47 (1), 64-77

MLA

차상원(Sangwon Cha),오은하(Eunha Oh),오세림(Selim Oh),한상범(Sang Beom Han),임호섭(Hosub Im). "바이오모니터링 프로그램을 위한 혈중 금속류 동시분석법 개발 및 확인 평가." 1. 한국환경보건학회지, 47.1(2021): 64-77

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제