흉부 CT검사시 AEC Program 적용에 의한 선량감소효과에 관한 연구

이용수 45

영문명
Dose Reduction Effect with Automatic Exposure Control Program in Chest CT
발행기관
대한CT영상기술학회
저자명
이대규(Dae kyoo Lee) 남윤철(Yoon Chul Nam) 김문찬(Moon Chan Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제8권 제1호, 15~23쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2006.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose The purpose of this study is to check how much a radiation dose of the thoraxis reduced when using AEC technique in CT examination, and to apply the program properly to clinical cases. Materials and Methods We measured organ doses of thyroid, upper chest, mid chest, lower chest, breast, liver when conducting a test by using Brilliance CT made by Philips, instead of AEC program, and compared the radiation dose reduction effect of each organ by measuring the effect shown when using D-DOM (a method of controlling a tube current according to the thickness of a subject for photography toward X-Y axis of a revolving angle of a tube) among AEC programs, and Z-DOM(a method of controlling a tube current according to the thickness of Z-axis position). Results The comparison between dose with AEC program and dose without AEC program in chest routine CT were as follows, 1. The thyroid dose using D-DOM and Z-DOM wasreduced 23.9% and 49.5% respectively rather than dose of non-AEC program. 2. The upper chest dose using D-DOM and Z-DOM was reduced 18.3% and 17.8% respectively rather than dose of non-AEC program. and The mid. chestdose using D-DOM and Z-DOM was reduced 15.2% and 12.7% respectively rather than dose of non-AEC program. and The lower chest dose using D-DOM and Z-DOM was reduced 5.8% and 22.4% respectively rather than dose of non-AEC program. 3. The breast dose using D-DOM and Z-DOM was reduced 10.7% and 7.5% respectively rather than dose of non-AEC program. 4. The liver dose using D-DOM and Z-DOM was reduced 20.3% and 26.4% respectively rather than dose of non-AEC program. 5. It was proven that as for the radiation dose reduction effect by D-DOM, the control of a tube current was mostly performed in the asymmetrical part such as shoulder when comparing upper chest (18.3%), mid. Chest(15.2%), and lower chest(5.8%). 6. Thyroid, Lower chest showed a greater radiation dose reduction effect when using Z-DOM rather than D-DOM. Conclusion The radiation dose reduction effect in each organ was proven higher by far when using AEC program. In particular, D-DOM demonstrated an excellent radiation dose reduction effect in the part that showed a great difference of thickness between AP and Lateral(ex. shoulder). Z-DOM displayed an outstanding effect in the neck part.

목차

Abstract
Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이대규(Dae kyoo Lee),남윤철(Yoon Chul Nam),김문찬(Moon Chan Kim). (2006).흉부 CT검사시 AEC Program 적용에 의한 선량감소효과에 관한 연구. 대한CT영상기술학회지, 8 (1), 15-23

MLA

이대규(Dae kyoo Lee),남윤철(Yoon Chul Nam),김문찬(Moon Chan Kim). "흉부 CT검사시 AEC Program 적용에 의한 선량감소효과에 관한 연구." 대한CT영상기술학회지, 8.1(2006): 15-23

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제