본문 바로가기

추천 검색어

실시간 인기 검색어

학술논문

Cardiac Functional Analysis를 위한 ECG-gated MDCT의 유용성과 MRI, SPECT, Echocardiography와의 비교분석

이용수 5

영문명
The Usefulness of ECG-gated MDCT for The Cardiac Functional Analysis; and Comparison with MRI, SPECT, Echocardiography
발행기관
대한CT영상기술학회
저자명
정한별(Han Byul Jeong) 김영옥(Young Ok Kim) 구본승(Bon Seung Goo) 대창민(Chang Min Dae) 민관홍(Gwan Hong Min) 김성룡(Seong Ryong Kim)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제8권 제1호, 127~136쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2006.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose In the evaluation of ischemic heart disease, accurate measurement of cardiac function is very important as well as the evaluation of vessel status of coronary artery. therefore we evaluate the accuracy of cardiac functional analysis using ECG-gated MDCT compare with other imaging modality such as MRI, single photon emission computed tomography and echocardiography. Materials and Methods We recruited 21 patients(age range:51~78, mean age:62.8±10.69, sex: male-13 female-8) with ischemic heart disease that underwent 4 exam(CT, MRI, single photon emission computed tomography and Echo) all within 1 month. We used 16 slice MDCT(Mx8000 IDT, Philips Medical Systems, Netherland) and dual injector(Medrad, USA). We measured 4 cardiac functional data(ejection- fraction %, end-diastolic volume, end-systolic volume and mass) of left ventricle. To measure data, we used end-systolic & end-diastolic reconstruction phase during cardiac cycle in ECG-gated cardiac CT. 4 cardiac functional data(EF, EDV, ESV and mass) were measured at short axis view using semiautomated contour technique in Extended Brilliance workstation(Brilliance version 2.0, Philips Medical Systems). This cardiac functional data obtained from CT was compared with MRI, ECG-gated single photon emission computed tomography, echocadiography. MRI is known to reference standard of cardiac function. therefore we analyzed the accuracy of cardiac functional data each modality(CT, single photon emission computed tomography, echocadiography) compared with MRIcardiac functional data as reference of standard. Results We analyze difference MRI with other modality(CT, single photon emission computed tomography, echocardiography). First, mean difference for the measurement of EF(%) is CT ±2.7, SPECT ±6.7, echocardiography: ±7.01. Second, end-diastolic volume(EDV) value(ml), mean of difference is CT: ±18.3, SPECT ±44.1 except echocardiography(because echocardiography is not volume but two dimentional diameter). Third, end-systolic volume(ESV) value(ml), mean of difference is CT: ±8.57, SPECT ±15.9 also except echocardiography. At last, left ventricle mass score is only compare MRI with CT and not include papillary muscle. Mean of difference is CT: ±8.09. Conclusion From thisstudy, we concluded that ECG-gated MDCT is more accurate than SPECT or echocardiography for the assessment of cardiac function. According to MDCT is rapidly developed like as 64 MDCT, improvement of temporal resolution bring to reduce artifact that is influenced heart rate. Therefore MDCT will play an important role in the near future for the evaluation of cardiac functional analysis.

목차

Ⅰ. 목적
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

정한별(Han Byul Jeong),김영옥(Young Ok Kim),구본승(Bon Seung Goo),대창민(Chang Min Dae),민관홍(Gwan Hong Min),김성룡(Seong Ryong Kim). (2006).Cardiac Functional Analysis를 위한 ECG-gated MDCT의 유용성과 MRI, SPECT, Echocardiography와의 비교분석. 대한CT영상기술학회지, 8 (1), 127-136

MLA

정한별(Han Byul Jeong),김영옥(Young Ok Kim),구본승(Bon Seung Goo),대창민(Chang Min Dae),민관홍(Gwan Hong Min),김성룡(Seong Ryong Kim). "Cardiac Functional Analysis를 위한 ECG-gated MDCT의 유용성과 MRI, SPECT, Echocardiography와의 비교분석." 대한CT영상기술학회지, 8.1(2006): 127-136

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제