전산화단층촬영장치의 품질관리 자동화 프로그램의 개발 및 적용에 관한 연구

이용수 0

영문명
Development and Application of an Automatic Program for Quality Control in Computed Tomography
발행기관
대한CT영상기술학회
저자명
김기홍(Ki Hong Kim) 이원구(Won Gu Lee)
간행물 정보
『대한CT영상기술학회지』대한전산화단층기술학회지 제8권 제1호, 53~62쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2006.04.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose To evaluate the automatic quality control program for minimize an error by person whom it measures of the phantom test in computed tomographic quality control examination. Material and Methods Quality control of phantom image were measured by conventional method and our new automatic quality control program. The Hough transformation was used for searching a circle and line composing of phantom image, and Canny’s method also was used in detection of edge. Results 1. A difference of attenuation coefficient of water was ranged from 0.3HU to 1.0HU, and mean difference was 0.13HU. 2. A difference of noise was ranged from 0HU to 0.1HU, and mean difference was 0.08HU. 3. There was a difference of 0.1HU in uniformity, and results were same in beam alignment accuracy test. 4. A difference in spatial resolution test was ranged from 0mm to 0.25mm, and mean difference was 0.19mm. 5. A difference of length accuracy test was ranged from 0mm to 0.2mm, and mean difference was 0.15mm between image and real phantom. And ranged 0 to 1 degree, and mean difference was 0.5 degree at angle accuracy test between image and real phantom. 6. A difference in contrast resolution test was ranged from 0mm to 6.3mm, and mean difference was 3.15mm. 7. A difference was ranged from 0.1mm to 0.3mm in 5mm slice thickness test, and mean difference was 0.23mm. And ranged from 0.8mm to 1.2mm, and mean difference was 0.8mm in 10mm slice thickness test. Conclusion An each items by our automatic quality control program for quality control in CT were showed a value less than standard one, we expect CT quality control can be examined by automatic program, if more systematic study is done.

목차

Abstract
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

김기홍(Ki Hong Kim),이원구(Won Gu Lee). (2006).전산화단층촬영장치의 품질관리 자동화 프로그램의 개발 및 적용에 관한 연구. 대한CT영상기술학회지, 8 (1), 53-62

MLA

김기홍(Ki Hong Kim),이원구(Won Gu Lee). "전산화단층촬영장치의 품질관리 자동화 프로그램의 개발 및 적용에 관한 연구." 대한CT영상기술학회지, 8.1(2006): 53-62

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제