DR Mammography에서 평균유선선량 감소를 위한 방안

이용수 14

영문명
The Study for Average Glandular Dose Reduction in Digital Mammography
발행기관
대한영상의학기술학회
저자명
조은혜(Eun Hye Cho) 이은주(Eun Joo Lee) 주미화(Mi Hwa Joo) 이관섭(Kwan Sup Lee) 하동윤(Dong Yoon Ha)
간행물 정보
『대한영상의학기술학회 논문지』2010년 춘계학술대회 논문지, 19~28쪽, 전체 10쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2010.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : In digital mammography, Exposure condition was automatically chosen using by measurement breast thickness and the density of mammary gland. It may cause a lack of recognition about an appropriate exposure condition and total exposure dose which would be high through the more increase dose and the image quality was better. For search a minimum dose at diagnosis and find a minimum scan parameter, in our study using an authorization standard breast phantom from ACR(American collage of radiology). Materials and methods : AOP mode of Digital mammography(Senographe DS) used with Standard, Contrast, Dose mode take every 3 times and archived 9 images for reproducibility in same parameters. In Manual mode, kVp was fixed 29 and mAs was changed from 40 to 4 in 11steps, it take every 3 times and archived 33 images for reproducibility in same parameters. Phantom image was evaluated and analze by SPSS program with mAs, phantom scoring, evaluation of false region, image quality, SNR and average glandular dose. Results : Average glandular dose is revealed the highest dose in contrast mode, the lowest dose in dose mode out of AOP mode. The scoring of false region was passed on ACR quality control standard, it was above 0.58mGy at average glandular dose(59% of standard mode) and 25mAs(61% of standard mode). It has a right statistical correlation. Do evaluations of false region with the naked eye, the order of correlation with average glandular dose was such as following speck, fiber, mass. It has a right statistical correlation. Also evaluation of image quality was above score 3(good) which more than 0.92mGy(93% of standard mode) and 40mAs(98% of standard mode). It has a right statistical correlation. SNR was satisfied with standard score, more than 0.58mGy average glandular dose(63% of standard mode), and 25mAs(61% of standard mode). It has a right statistical correlation, too. Conclusion : The image quality of possibly diagnosis could maintain by low average glandular dose and mAs by Manual mode which less than AOP mode parameters of the existing digital mammography. Also it could reduce average glandular dose. Also it could change minimum parameters accompany with a shape of lesion. This method is innovative plan of reduction of patient dose about unnecessary radiation exposure by using a AOP mode but Manual mode with previous reference parameters when follow-up study and post operation patient exam.

목차

Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

조은혜(Eun Hye Cho),이은주(Eun Joo Lee),주미화(Mi Hwa Joo),이관섭(Kwan Sup Lee),하동윤(Dong Yoon Ha). (2010).DR Mammography에서 평균유선선량 감소를 위한 방안. 대한영상의학기술학회 논문지, 2010 (1), 19-28

MLA

조은혜(Eun Hye Cho),이은주(Eun Joo Lee),주미화(Mi Hwa Joo),이관섭(Kwan Sup Lee),하동윤(Dong Yoon Ha). "DR Mammography에서 평균유선선량 감소를 위한 방안." 대한영상의학기술학회 논문지, 2010.1(2010): 19-28

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제