학술논문
유방촬영술에서 방사선 반 투과성(Radiolucent) 패드(Mammo Pad)의 유용성 관한 고찰
이용수 28
- 영문명
- A Study of the Utility of Radiolucent Mammo Pad in Mammography
- 발행기관
- 대한영상의학기술학회
- 저자명
- 김도희(Do Hee Kim) 이지영(Ji Young Lee) 최은영(Eun Young Choi) 김인수(In Soo Kim) 김동성(Dong Sung Kim)
- 간행물 정보
- 『대한영상의학기술학회 논문지』2010년 춘계학술대회 논문지, 9~17쪽, 전체 9쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.03.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose : When it comes to Mammography, pain and inconvenience that come from compression have existed for a while. Regarding this issue, I would like to study the utility of the radiolucent Mammo Pad to reduce the pain during the Mammography.
Materials and Methods : For last three months from March 2009 to May 2009, we carried out examinations on 400 people (One hundred people in 30s, 40s, 50s, and 60~70s each) who did not go through Resection and plastic surgery among those who came to Gangnam Center, SNUH Hospital. With those 400 objects, we let them use the Mammo Pad on their right breast and not use on their left breast and then conducted Cranio-Caudal and Mediolateral-Oblique examinations.
The method that we used is that during the examination we compared Compression Force and Exposure Dose (kVp, mAs). Moreover, right after Mammography, through questioning, we checked whether the Compression pain had been reduced when using the Mammo Pad. We also used ACR Mammo Phantom to measure whether the quality of the image has changed or not when using the Mammo Pad.
Results : Through questioning patients in different age groups, we found that average 88 percent of them (352/400) experienced the Compression-related-pain reduction when using the Mammo Pad. By comparing Compression Force (daN) of those who used the Mammo Pad and those who did not in different age groups, we discovered that the daN of those who used the Mammo Pad increased by average 14~15 percent compared to those who did not use the Mammo Pad. Exposure dose decreased by average 0-0.2 percent and mAs also decreased by 5.8~6.8 percent. Refering to the clinical image checklist, five radiologists examined the ACR Mammo Phantom images depending on the usage of the Pad. As a result, we found that when using the pad the score was 12.8 out of the total score of 16. In contrast, when not using the Mammo Pad, the score was 11.5 and the Total score was more than 10. Therefore, we can say this result satisfies the Radiodiagnosis safety management standard.
Conclusion : When it comes to Mammography, the usage of Radiolucent Mammo Pad did not eliminate the issue of the Compression, but it surely reduced the natural pain and the inconvenience regarding the compression without lowering the quality of the image. Furthermore, I feel convinced that the difficulty of the radiologists and patients for the effective examination will be solved. At the same time, it is very meaningful that the reduction in Radiation Exposure dose is possible and so, it is thought that there is a continuous need for the reduction in Exposure Dose (kVp, mAs).
목차
Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰 및 결론
참고문헌
해당간행물 수록 논문
- 담관 결석 발생과 재발에 있어 십이지장 팽대부 주위 게실과의 상관관계
- Source Image Distance 변화에 따른 환자 및 검사자의 피폭선량 비교
- 유방촬영술에서 방사선 반 투과성(Radiolucent) 패드(Mammo Pad)의 유용성 관한 고찰
- 수술 중 X-ray 검사 시 Cassette Draping에 대한 고찰
- 방사선투시장비를 사용한 검사에 참여하는 소화기내과 소속 간호사들의 의료용 방사선에 대한 의식도 조사
- 폐경기 여성에서 DXA를 이용한 Lateral Vertebral Assessment의 유용성
- 조기크론병 환자의 진단에 있어서 임상양상과 성격유형의 비교분석에 따른 Peroral Pneumocolon Technique의 유용성
- 선원에서 X선 방어용 칸막이간 거리가 상이한 유방촬영실의 공간 산란선량 비교
- Fracture of Hamate Hook의 유용한 방사선 단순촬영법에 대한 고찰
- 투시조영검사 시 환자 피폭선량 저감화 대책에 관한 연구
- 소아 투시조영검사 시 Pulse rate별 화질분석을 통한 저선량 모드 선택에 관한 연구
- 개선된 Fulcrum을 이용한 Bending radiograph의 유용성에 관한 고찰
- 고관절 표면 치환술 환자의 LATERAL 검사법에 대한 고찰
- Shoulder Rockwood 검사법에서 Position 변화에 따른 Image Quality 향상을 위한 연구
- DR Mammography에서 평균유선선량 감소를 위한 방안
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!