학술논문
고관절 표면 치환술 환자의 LATERAL 검사법에 대한 고찰
이용수 58
- 영문명
- Reflecting the Lateral Screening Test Method to Resurfacing Hip Joint Arthroplasty Patients
- 발행기관
- 대한영상의학기술학회
- 저자명
- 정구민(Ku Min Jung) 박명래(Myung Rae Park) 이춘미(Chun Mi Lee) 박석(Suk Park) 최상규(Sang Kyoo Choi) 김용환(Young Hwan Kim)
- 간행물 정보
- 『대한영상의학기술학회 논문지』2010년 춘계학술대회 논문지, 35~45쪽, 전체 11쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.03.30
4,120원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose : During the follow- up test of resurfacing hip joint arthroplasty patients, the lateral screening test is usually taken to distinguish wear, tear, debris, or osteolysis, when the boundaries of the bone and the implant are described as a single line. So far, however, there is no reported radiologic data about effective test method for accurate information processing and image description, so far. Therefore, we comparatively analyzed the effectiveness of methods by measuring time of lateral screening test useful for diagnosis and temporizing translateral test.
Matherials and Methods : 200 follow-up patients (152 men, 48 women) of resurfacing hip joint arthroplasty, who had visited our hospital from April 2009 to January 2010 were subjected for this study, and their average age was 44.9 years (20~78 years old). ① 12 university hospitals including us were subjected for the survey of whether the resurfacing hip joint arthroplasty was held or not, and about the lateral test method. ② We classified and measured the femur angle at the hip AP(Internal rotation 15°) position into 5 groups (A:120°~125°, B:125°~130°, C:130°~135°, D:135°~140°, E:140°~145°) by PACS and analyzed the distribution. We also classified the incident beam into 4 groups (Cranial 30°, 35°, 40°, 45°), tested the effective incident beam(Tube angle) for diagnosis by femur angle, asked for screening by faculties, residents, and radiologists of the department of radiology and orthopedics, and finally analyzed statistically by Chi- square verification.
③ We comparatively analyzed the diagnostic effectiveness and work efficiency of temporizing translateral test with the published experimental method, during the lateral test for resurfacing hip joint arthroplasty patients.
Results : ① 5 of 12 university hospitals provided resurfacing hip joint arthroplasty treatment, while only our hospital was proved to conduct an independent test method. ② The result of Chi-square test(P-Value=0.001) showed the maximal femur angle distribution at 125°~140°, and the most useful image for diagnosis was obtained from the result of 129 of 200 patients showing the incident beam(Tube angle) at Cranial 35°~40°.
③ Both groin lateral test and translateral test provided useful images for diagnosis. But, the groin lateral test method could improve the problems of translateral test method about the reproducibility of incident beam and the low repeat rate of measurement. Also, the efficiency of test was much higher by reducing average measurement time for more than 2 times (40.85 sec vs 82.85 sec).
Conclusion : From this study subjecting the follow-up patients of resurfacing hip joint arthroplasty, the result of lateral screening test showed the best image with the incident angle by Cranial 35°~40° to find out wear, tear, debris, or osteolysis between the bone and the implant. In addition, the time also reduced by more than 2 times compared to the temporizing method.
목차
Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
키워드
해당간행물 수록 논문
- 담관 결석 발생과 재발에 있어 십이지장 팽대부 주위 게실과의 상관관계
- Source Image Distance 변화에 따른 환자 및 검사자의 피폭선량 비교
- 유방촬영술에서 방사선 반 투과성(Radiolucent) 패드(Mammo Pad)의 유용성 관한 고찰
- 수술 중 X-ray 검사 시 Cassette Draping에 대한 고찰
- 방사선투시장비를 사용한 검사에 참여하는 소화기내과 소속 간호사들의 의료용 방사선에 대한 의식도 조사
- 폐경기 여성에서 DXA를 이용한 Lateral Vertebral Assessment의 유용성
- 조기크론병 환자의 진단에 있어서 임상양상과 성격유형의 비교분석에 따른 Peroral Pneumocolon Technique의 유용성
- 선원에서 X선 방어용 칸막이간 거리가 상이한 유방촬영실의 공간 산란선량 비교
- Fracture of Hamate Hook의 유용한 방사선 단순촬영법에 대한 고찰
- 투시조영검사 시 환자 피폭선량 저감화 대책에 관한 연구
- 소아 투시조영검사 시 Pulse rate별 화질분석을 통한 저선량 모드 선택에 관한 연구
- 개선된 Fulcrum을 이용한 Bending radiograph의 유용성에 관한 고찰
- 고관절 표면 치환술 환자의 LATERAL 검사법에 대한 고찰
- Shoulder Rockwood 검사법에서 Position 변화에 따른 Image Quality 향상을 위한 연구
- DR Mammography에서 평균유선선량 감소를 위한 방안
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!