학술논문
개선된 Fulcrum을 이용한 Bending radiograph의 유용성에 관한 고찰
이용수 0
- 영문명
- The Usefulness of the Self-made Fulcrum in Bending Radiography
- 발행기관
- 대한영상의학기술학회
- 저자명
- 이효진(Hyo Jin Lee) 김상현(Sang Hyun Kim) 김동주(Dong Joo Kim) 김형철(Hyung Cheol Kim) 최천규(Cheon Kyu Choi)
- 간행물 정보
- 『대한영상의학기술학회 논문지』2010년 춘계학술대회 논문지, 47~51쪽, 전체 5쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2010.03.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose : The quality of Bending Radiography is determined as how well the curvature of the spine gets straightened for the evaluation of the flexibility of spine curvature and the prognosis of operation. The methods in conventional fulcrum have disadvantages: a physician is needed to apply the pressure and exposed to radiation and the force exerted is difficult to standardize. We studied the usefulness of the self-made fulcrum in Bending Radiography comparing the conventional fulcrum.
Materials and Methods : Fifty five patients (male: 19, female: 39, meanage: 15 years old) underwent in either conventional or self-made fulcrum in Bending Radiographyfrom January 2008 to July 2009. Also ten volunteers were answered the questionnaire about the pain, comfort, stability, reliability of the examination after positioned in the same condition like a patient and scored a point to each item from 1 to 5 (very bad to excellent). We alternatively used a conventional fulcrum (rectangular Styrofoam, a several size of padded cylinder) or the self-made fulcrum which is shaped a padded semicircle with a roller to control a height. An X-ray equipment (PHLIPS VM, Phillips Medical System, Nederland) was used for Bending Radiography. Ten patients who are between 20-30 degree of cobb’s angle among 55 patients were compared and evaluated respectively in conventional and self-made Fulcrum.
Results: The changes of cobb’s angle in conventional Fulcrum and self-made Fulcrum were 9±4.8 and 16±2.0 respectively. The scores of the questionnaire in the conventional and self-made Fulcrum were 3.3±0.6 and 2.7±0.9 in pain, 3.1±0.7 and 2.2±1.07 in comfort, 3.3±0.9 and 2.5±0.9 in stability, 2.6±0.8 and 3.8±0.8 in reliability of examination.
Conclusion : In Bending Radiography using self-made fulcrum, a physician was not needed to apply the pressure and no radiation was exposed, the curvature of the spine got better straightened than in conventional fulcrum, the pain of examination was decreased and reliability of it was increased, and however the comfort and stability of examination were a little lower than the conventional fulcrum because the position of patient was lateral decubitus, Finally, the self-made fulcrum in Bending Radiography showed the usefulness clinically when we consider the radiation of physician.
목차
Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
키워드
해당간행물 수록 논문
- 담관 결석 발생과 재발에 있어 십이지장 팽대부 주위 게실과의 상관관계
- Source Image Distance 변화에 따른 환자 및 검사자의 피폭선량 비교
- 유방촬영술에서 방사선 반 투과성(Radiolucent) 패드(Mammo Pad)의 유용성 관한 고찰
- 수술 중 X-ray 검사 시 Cassette Draping에 대한 고찰
- 방사선투시장비를 사용한 검사에 참여하는 소화기내과 소속 간호사들의 의료용 방사선에 대한 의식도 조사
- 폐경기 여성에서 DXA를 이용한 Lateral Vertebral Assessment의 유용성
- 조기크론병 환자의 진단에 있어서 임상양상과 성격유형의 비교분석에 따른 Peroral Pneumocolon Technique의 유용성
- 선원에서 X선 방어용 칸막이간 거리가 상이한 유방촬영실의 공간 산란선량 비교
- Fracture of Hamate Hook의 유용한 방사선 단순촬영법에 대한 고찰
- 투시조영검사 시 환자 피폭선량 저감화 대책에 관한 연구
- 소아 투시조영검사 시 Pulse rate별 화질분석을 통한 저선량 모드 선택에 관한 연구
- 개선된 Fulcrum을 이용한 Bending radiograph의 유용성에 관한 고찰
- 고관절 표면 치환술 환자의 LATERAL 검사법에 대한 고찰
- Shoulder Rockwood 검사법에서 Position 변화에 따른 Image Quality 향상을 위한 연구
- DR Mammography에서 평균유선선량 감소를 위한 방안
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!