학술논문
A PC-Based Monte Carlo Program과 유리선량계를 이용한 장기선량 및 유효선량 평가
이용수 26
- 영문명
- Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program and Glass Dosimeter
- 발행기관
- 대한영상의학기술학회
- 저자명
- 최원근(Weon Keun Choi) 김재인(Jae Yin Kim) 홍준기(Joon Ki Hong) 김성진(Seong Jin Kim) 이관섭(Kwan Sub Lee) 하동윤(Dong Yoon Ha)
- 간행물 정보
- 『대한영상의학기술학회 논문지』2009년 춘계학술대회 논문지, 131~138쪽, 전체 8쪽
- 주제분류
- 의약학 > 방사선과학
- 파일형태
- 발행일자
- 2009.03.30
4,000원
구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.
국문 초록
영문 초록
Purpose : The purpose of this study is to examine the utility of PCXMC by comparing organ dose based on statistical data obtained from Monte Carlo of program and organ dose obtained from the method using phantom and glass dosimeter.
Materials and Methods : 1. Direct method (the method of measurement using Glass Dosimeter) :
GD3.52M (GD3.52M will be referred to as element ) is inserted in the center of each organ. To calculate HVL and entrance exposure dose(mR), Unfors Xi meter is attached to around center of phantom entrance surface. To calculate ESD, five elements were attached around fields. Chest PA, Chest Lat, L-spine AP, L-spine Lat, Pelvis AP, and Skull PA are irradiated as Protocol of this hospital.
2. indirect method (the method using PCXMC program) : PCXMC program minimizes Error (%) by entering the same parameter as direct method on the hypothetical mathematical phantom The same age, stature, weight, and Focus-Skin Distance as Examination data of RANDO phantom are input and the FOV is drawn in the very same position. 16 organ doses are compared and analyzed which are the same as glass dosimeter among 29 organ doses obtained from inputting doses in PCXMC.
Results : 1. Organ doses : In all six tests, when comparing between PCXMC within FOV and others with organ doses in glass dosimeter, they are significant with each other (p<0.05). With relation to Out of FOV organ dose of Chest PA, Chest Lat, Pelvis AP, and Skull PA, the difference in terms of statistic is significant (p<0.05).
2. Effective dose : In Chest PA, and Chest Lat, effective dose using PCXMC is 0.0453, 0.1542 and effective dose using glass dosimeter is 0.0527, 0.1699 and shows the difference of 14% and 9% respectively. In Skull PA, organ dose using PCXMC program is 0.0209 and organic dose using glass dosimeter is 0.0209 and therefore they show the same result. In L-spine AP, and Lat, effective dose using PCXMC is 0.5635, 0.4794 and effective dose using glass dosimeter is 0.7845, 0.6301 and in other words, 28%, 23% respectively. The method of measurement using glass dosimeter is higher than that of measurement using PCXMC. In Pelvis AP, effective dose using PCXMC is 0.4709 and effective dose using glass dosimeter is 0.6833 and the difference is 31%.
Conclusion : 1. Organ dose : In cases of organ dose using glass dosimeter and organ dose using PCXMC program and Chest PA, Chest Lat, Pelvis AP and Skull PA in which there is the difference of average, they are organ dose out of FOV and low dose. In case predose measurement value is less than 30uGy of organ dose, there is difference in measurement value in between organ dose using PCXMC program and organic dose using glass dosimeter. 2. Effective dose : In Chest PA, Lat, and Skull PA which show low effective dose, effective dose using PCXMC program and effective dose using glass dosimeter show similar result. In L-spine, Lat, and Pelvis AP with high effective, effective dose using glass dosimeter compared with effective dose using PCXMC program is measured high consistently.
목차
Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰
Ⅴ. 결론
참고문헌
해당간행물 수록 논문
- 유리선량계를 사용하여 Colon study 중 검사자가 받게 되는 산란선량 측정을 통한 고찰
- 투시와 저격촬영 중 검사실내 거리에 따른 인체부위별 누설선량의 비교분석
- 부가필터 사용에 따른 환자피폭선량 저감 평가
- Digital Radiography Chest PA 촬영 시 SID 감소에 따른 선량과 영상평가에 관한 연구
- MCNPX 몬테카를로 시뮬레이션을 이용한 Co-60과 Cs-137 방사핵종의 감마상수 확인
- C-arm 투시 사용 시 방향과 거리에 따른 입사선량
- 위절제술을 시행한 조기위암환자에서 위치확인을 위한 위장조영검사와 위내시경검사의 비교분석에 따른 진단률 향상에 관한 연구
- 상부 위장관 조영 검사 전 동영상 시청을 통한 검사 효율성 증대 방안
- 측두하악관절 CINE 기법의 유용성에 대한 고찰
- Telos Stress Device에 대한 정도관리메뉴얼 및 실태 조사
- VCUG 검사 중 피폭선량에 관한 고찰
- Chest PA 검사 시 피검자의 Effective Dose(유효선량)에 관한 고찰
- DR System에서 L-Spine 검사 시 HVT(High Voltage Technique)의 유용성
- Tube 방향에 따른 조종실에서의 산란선에 관한 연구
- CT에서 조영제 주입검사와 Non Contrast IVP 검사의 연구
- 투시조영 검사에서의 면적선량의 측정 및 비교
- C-arm 사용 시 환자 피폭선량 저감에 관한 연구
- 유두 분비물을 원인으로 하여 시행한 Galactography의 유용성에 관한 고찰
- 격자와 초점간 거리에 따른 Cut-Off 현상
- 표준 촬영기법(식품의약품안전처)을 기준으로 한 Skull A-P 촬영 시 Lens의 피폭선량감소를 위한 촬영조건 연구
- 영유아 복부 선자세 촬영시 보조기구의 활용이 영상에 미치는 영향
- 일반촬영의 대기시간 단축을 위한 Process 개선에 따른 기대효과
- 의료용 모니터 정도관리 방법을 이용한 일반용 모니터 정도관리 사례연구
- A PC-Based Monte Carlo Program과 유리선량계를 이용한 장기선량 및 유효선량 평가
참고문헌
관련논문
의약학 > 방사선과학분야 BEST
- 의료용 인공지능에 대한 동향 분석 및 방사선사 인식조사
- CT contrast 검사 시 중심 정맥관을 이용한 조영제 사용에 대한 연구
- CT조영제 부작용 고위험군에 대한 전처치의 유용성
의약학 > 방사선과학분야 NEW
- 초음파 조직검사에 사용되는 Biopsy Gun Needle의 재질에 따른 반사율 연구
- 방사선에 대한 지식 및 인식도 연구
- 입원환자 일반촬영 이용량 및 피폭선량: 2018년 입원환자데이터
최근 이용한 논문
교보eBook 첫 방문을 환영 합니다!
신규가입 혜택 지급이 완료 되었습니다.
바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!