Tube 방향에 따른 조종실에서의 산란선에 관한 연구

이용수 4

영문명
Tube in the Direction of the Control Room Scattering Rray to Study
발행기관
대한영상의학기술학회
저자명
오동훈(Dong Hun Oh) 김병기(Byung Ki Kim) 김기정(Ki Jeong Kim) 이민우(Min Woo Lee) 김순배(Soon Bae Kim)
간행물 정보
『대한영상의학기술학회 논문지』2009년 춘계학술대회 논문지, 153~158쪽, 전체 6쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : Since X-ray was discovered by Roentgren in 1895, the bombed by X-ray has been the biggest part of artificial radiation. It’s definite that biological tissue reactions when it’s exposed by radiation. Even a very small amount of the bombed by radiation, if someone is exposed for a long time of many times, it takes some risk like leukemia and genetic influence. So we’d better make a smaller bombed circumstance for radiolotechnologists. In Kon-kuk University Medical Center, we installed the direction of tube toward the control room for the sake of patients. So from this case, what I want to know is how x-ray and scattering ray influence to radiolotechnologists. Materials and Methods : We measured scattering ray for three months from Oct 1, 2008 to Nov 31, 2008 in diagnostic radiology examination room We made two group A and B, three each, and then we installed total six TLD. Results : The average superficial dose of group A is 0.090 mSv and that of group B is 0.157 mSv. So the average superficial dose of group A is about 57% of that of group B. And average of group A is 0.093 mSv and that of group B is 0.150 mSv. So group A is about 62% of group B. Conclusion : The amount of radiation between group A and B makes 1.5 times difference. The reason the amount of radiation of group B which has a door between the control room and the exam room is higher, let alone influence of lead glass. We make the direction of tube toward the control room. This measurement can be compared with effective radiation which is generally performed in hospitals. The effective radiation of chest PA exam is 0.02 mSv, and that of lateral exam is 0.04 mSv. Also skull AP and lateral exam are 0.04 mSv. From this result, even it’s less than 0.2 mSv, from the study for 3months, we can’t neglect that. So we can know that if possible we should try to place tube not toward the control room Like Kon-kuk University Medical Center, in the case that tube is installed toward the control room for the patients’ sake, we University Medical Center, in the case that tube is installed toward the control room for the patients’ sake, we should try to minimalize the effect to radiolotechnologists using portable lead glass or shieling.

목차

Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
Ⅳ. 고찰 및 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

오동훈(Dong Hun Oh),김병기(Byung Ki Kim),김기정(Ki Jeong Kim),이민우(Min Woo Lee),김순배(Soon Bae Kim). (2009).Tube 방향에 따른 조종실에서의 산란선에 관한 연구. 대한영상의학기술학회 논문지, 2009 (1), 153-158

MLA

오동훈(Dong Hun Oh),김병기(Byung Ki Kim),김기정(Ki Jeong Kim),이민우(Min Woo Lee),김순배(Soon Bae Kim). "Tube 방향에 따른 조종실에서의 산란선에 관한 연구." 대한영상의학기술학회 논문지, 2009.1(2009): 153-158

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제