투시조영 검사에서의 면적선량의 측정 및 비교

이용수 12

영문명
The Measurement & Comparison of DAP on Fluoroscopy Studies : Esophagography, UGI Series, Swallowing Study
발행기관
대한영상의학기술학회
저자명
노현아(Hyun A Noh) 조한영(Han Yeong Cho) 문규오(Kyoo O Moon) 손순룡(Soon Lyong Son)
간행물 정보
『대한영상의학기술학회 논문지』2009년 춘계학술대회 논문지, 15~23쪽, 전체 9쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.03.30
4,000

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : This thesis is, esophagography, UGI series, swallowing study using DAP meter measure in checking and fluoroscopy time, body weight, to learn about the correlation with image number, compared with earlier studies and seek the ways of reducing the radiation dose. Materials and Methods : October- December 2008 was an experiment of 212 patients. Philips has used its equipment, DAP meter adherent in front of X-ray tube calibration, and using the ion-chamber. By checking the patients weight, fluoroscopy time, image number and DAP values were measured. Results : According to the increase in esophagography fluoroscopy time as an increase in the DAP had paid attention to statistics (P<0.05). In UGI series, according to the increase in weight, fluoroscopy time, image number as an increase in the DAP had paid attention to statistics (P<0.05). In swallowing study, fluoroscopy time and DAP had paid attention to statistics (P<0.05). In all test, depending on the increase in fluoroscopy time also DAP had increased gradually. In case of our hospital, the average DAP and fluoroscopy time with advanced studies to compare at least 2.4 times, respectively, 6.5 times as high was investigating. In UGI series, fluoroscopy time at least 1.7 times, DAP 2.6 times, image number also was 2.4 time higher. Conclusion : To reduce patient dose for fluoroscopy examination, in here and now, they should evaluate patient dose and accurately analyze related factors of exposure dose. It comes to the conclusion that patient dose is reduced in good image quality by perfonning the examinations for reference of advanced studies or recommend dose recommended dose in international organizations.

목차

Abstact
Ⅰ. 서론
Ⅱ. 대상 및 방법
Ⅲ. 결과
IV. 고찰
Ⅴ. 결론
참고문헌

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

노현아(Hyun A Noh),조한영(Han Yeong Cho),문규오(Kyoo O Moon),손순룡(Soon Lyong Son). (2009).투시조영 검사에서의 면적선량의 측정 및 비교. 대한영상의학기술학회 논문지, 2009 (1), 15-23

MLA

노현아(Hyun A Noh),조한영(Han Yeong Cho),문규오(Kyoo O Moon),손순룡(Soon Lyong Son). "투시조영 검사에서의 면적선량의 측정 및 비교." 대한영상의학기술학회 논문지, 2009.1(2009): 15-23

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제