격자와 초점간 거리에 따른 Cut-Off 현상

이용수 144

영문명
발행기관
대한영상의학기술학회
저자명
이정우 오지훈 임창성 진현규 전건일 이다혜 김영남 이인자
간행물 정보
『대한영상의학기술학회 논문지』2009년 춘계학술대회 논문지, 197~197쪽, 전체 1쪽
주제분류
의약학 > 방사선과학
파일형태
PDF
발행일자
2009.03.30
무료

구매일시로부터 72시간 이내에 다운로드 가능합니다.
이 학술논문 정보는 (주)교보문고와 각 발행기관 사이에 저작물 이용 계약이 체결된 것으로, 교보문고를 통해 제공되고 있습니다.

1:1 문의
논문 표지

국문 초록

영문 초록

Purpose : The grid in one of the most effective ways to eliminate scattered radiation is shown a specified FD (focus distance). We for FGD (focusgrid distance) grid specified regulation range of the FD widely in FGD the grid to minimize the cut-off phenomenon due to changes. In case can not keep a specified FD is displayed on grid to evaluate find best FGD to minimize cut-off phenomenon. Materials and Methods : 85 lines/inch, FD: 100 ~ 180 ㎝ and 103 lines/inch, FD: 100 ㎝ in the X-ray imaging apparatus , grid ratio (6:1, 8:1, 10:1, 12:1) and measuring the transmission while changing the dose of the FGD 7.5 ㎝ and 15 ㎝ to right and left (LㆍR) from the center of gravity and the center (0 ㎝) of grid to the grid in the center the dose was calculated to 100% and the transmission dose (%) of right and left distance. Results : 1. is FGD 100, 150, 180, 200 ㎝ in the dose of L transmitting to R 15 ㎝ (%) was defined for both IEC. 2. 50 ㎝ 10 in FGD: 1, 12:1 in the lattice portion is transmitted through the dose (%) was not appropriate to the IEC standard with more than 60%. 3. impact of the transmission attenuation difference between the lowest dose is 150 ㎝ when the FGD days. 4. impact was greater than 50 ㎝ when the transmission is in accordance with dose attenuation difference FGD change is 150 cm. 5. Even if the same distance great influence higher ratio grid. Conclusion : If the grid is in the range of regulation FD designated broadly FD of mid-point of minimum distance and maximum distance suitable and to be suitable for use remotely rather than using if not keep the specified FD of the grid has to close the FGD the feed. In addition, even the same distance, it is necessary to identify a higher grid ratio of the FD and the attenuation difference in the non-grid using the X-ray imaging apparatus to be adjusted due to the size of the recording conditions.

목차

키워드

해당간행물 수록 논문

참고문헌

교보eBook 첫 방문을 환영 합니다!

신규가입 혜택 지급이 완료 되었습니다.

바로 사용 가능한 교보e캐시 1,000원 (유효기간 7일)
지금 바로 교보eBook의 다양한 콘텐츠를 이용해 보세요!

교보e캐시 1,000원
TOP
인용하기
APA

이정우,오지훈,임창성,진현규,전건일,이다혜,김영남,이인자. (2009).격자와 초점간 거리에 따른 Cut-Off 현상. 대한영상의학기술학회 논문지, 2009 (1), 197-197

MLA

이정우,오지훈,임창성,진현규,전건일,이다혜,김영남,이인자. "격자와 초점간 거리에 따른 Cut-Off 현상." 대한영상의학기술학회 논문지, 2009.1(2009): 197-197

결제완료
e캐시 원 결제 계속 하시겠습니까?
교보 e캐시 간편 결제